Monitoring for the Refusol 020K inverters. The on-site poller POSTs each 60 s cycle to /api/readings; the dashboard answers first whether every inverter is operating and whether one is producing far less than its peers (string fuse / breaker problems). - Backend: FastAPI + SQLite. Parameters defined once in fields.py (columns auto-added on start); unknown poller keys are kept in `extra` since the parameter map is still being researched. Idempotent ingest, daily energy rollup in site-local days, history downsampling, 2-year retention. - Health: Offline vs Sleeping (sun elevation) vs No data (datalogger silent, detected via empty-batch heartbeats), Fault from error_code, underperformance vs fleet median (per kWp when sizes set), MPPT imbalance. - Frontend: mobile-first React + Tailwind, installable PWA, comparison bars, 24 h power / 30 day energy charts, detail page with all parameters. - Docker: backend + frontend + nginx on one port for NPM, as in bellsystems-cp; deploy-host.sh pulls main and rebuilds. - poller/backend_client.py: stdlib client with offline spool for refusol_poller.py; fake_poller.py simulates the site. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
61 lines
2.3 KiB
Markdown
61 lines
2.3 KiB
Markdown
# On-site poller
|
||
|
||
`refusol_poller.py` (not in this repo yet) reads the inverters over USS/TCP
|
||
(port 21062, USS address 0). It sends each cycle to the backend through
|
||
`backend_client.py` — copy that file next to the poller.
|
||
|
||
## Wiring it into `refusol_poller.py`
|
||
|
||
At the top of the file:
|
||
|
||
```python
|
||
from backend_client import BackendClient
|
||
|
||
BACKEND_URL = "https://solar.bonamin.net"
|
||
API_KEY = "same value as API_KEY in the server's .env"
|
||
|
||
backend = BackendClient(BACKEND_URL, API_KEY)
|
||
```
|
||
|
||
At the end of every poll cycle, one dict per inverter that answered:
|
||
|
||
```python
|
||
readings = []
|
||
for inverter_id, values in polled.items(): # however the poller holds them
|
||
readings.append({"inverter_id": inverter_id, **values})
|
||
backend.send(readings) # also call it when the list is empty
|
||
```
|
||
|
||
Each dict uses the keys below (all optional — send what was read). Anything
|
||
else you include (e.g. a newly discovered parameter as `"p0xx_raw": 1234`) is
|
||
stored too and shows under "Other (unmapped)" on the inverter page.
|
||
|
||
| key | unit | source |
|
||
|---|---|---|
|
||
| `ac_voltage_l1_v` / `_l2_v` / `_l3_v` | V | P050 / P05B / P064 raw / 40 |
|
||
| `dc_voltage_mppt1_v` / `_mppt2_v` | V | P052 / P054 raw / 40 |
|
||
| `dc_current_mppt1_a` / `_mppt2_a` | A | P05A / P05C raw / 10 |
|
||
| `ac_current_l1_a` / `_l2_a` / `_l3_a` | A | P068 / P069 / P06A raw / 100 |
|
||
| `ac_power_total_w` | W | P06D raw |
|
||
| `grid_frequency_hz` | Hz | P06C raw / 20 |
|
||
| `temperature_c` | °C | P070 raw >> 16 |
|
||
| `daily_energy_wh` | Wh | P063 IND=0 raw × 10 |
|
||
| `total_energy_wh` | Wh | P063 IND=11 raw |
|
||
| `status_code` | – | inverter state, once identified |
|
||
| `error_code` | – | non-zero = fault (shows the inverter as **Fault**) |
|
||
| `status_text` | – | optional human text for the code |
|
||
|
||
`send()` stamps each reading with the current UTC time, buffers to
|
||
`unsent_readings.jsonl` when the internet is down and re-sends later, and
|
||
never raises — a backend problem can't stop the polling loop.
|
||
|
||
**Call `send([])` even when no inverter answered.** That's the heartbeat that
|
||
lets the dashboard say "inverter not responding" (site online) instead of
|
||
"datalogger offline" (site/internet down).
|
||
|
||
## Trying the dashboard without the site
|
||
|
||
```bash
|
||
python fake_poller.py --url http://localhost:8090 --key change-me --backfill-days 30
|
||
```
|