Monitoring for the Refusol 020K inverters. The on-site poller POSTs each 60 s cycle to /api/readings; the dashboard answers first whether every inverter is operating and whether one is producing far less than its peers (string fuse / breaker problems). - Backend: FastAPI + SQLite. Parameters defined once in fields.py (columns auto-added on start); unknown poller keys are kept in `extra` since the parameter map is still being researched. Idempotent ingest, daily energy rollup in site-local days, history downsampling, 2-year retention. - Health: Offline vs Sleeping (sun elevation) vs No data (datalogger silent, detected via empty-batch heartbeats), Fault from error_code, underperformance vs fleet median (per kWp when sizes set), MPPT imbalance. - Frontend: mobile-first React + Tailwind, installable PWA, comparison bars, 24 h power / 30 day energy charts, detail page with all parameters. - Docker: backend + frontend + nginx on one port for NPM, as in bellsystems-cp; deploy-host.sh pulls main and rebuilds. - poller/backend_client.py: stdlib client with offline spool for refusol_poller.py; fake_poller.py simulates the site. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2.3 KiB
On-site poller
refusol_poller.py (not in this repo yet) reads the inverters over USS/TCP
(port 21062, USS address 0). It sends each cycle to the backend through
backend_client.py — copy that file next to the poller.
Wiring it into refusol_poller.py
At the top of the file:
from backend_client import BackendClient
BACKEND_URL = "https://solar.bonamin.net"
API_KEY = "same value as API_KEY in the server's .env"
backend = BackendClient(BACKEND_URL, API_KEY)
At the end of every poll cycle, one dict per inverter that answered:
readings = []
for inverter_id, values in polled.items(): # however the poller holds them
readings.append({"inverter_id": inverter_id, **values})
backend.send(readings) # also call it when the list is empty
Each dict uses the keys below (all optional — send what was read). Anything
else you include (e.g. a newly discovered parameter as "p0xx_raw": 1234) is
stored too and shows under "Other (unmapped)" on the inverter page.
| key | unit | source |
|---|---|---|
ac_voltage_l1_v / _l2_v / _l3_v |
V | P050 / P05B / P064 raw / 40 |
dc_voltage_mppt1_v / _mppt2_v |
V | P052 / P054 raw / 40 |
dc_current_mppt1_a / _mppt2_a |
A | P05A / P05C raw / 10 |
ac_current_l1_a / _l2_a / _l3_a |
A | P068 / P069 / P06A raw / 100 |
ac_power_total_w |
W | P06D raw |
grid_frequency_hz |
Hz | P06C raw / 20 |
temperature_c |
°C | P070 raw >> 16 |
daily_energy_wh |
Wh | P063 IND=0 raw × 10 |
total_energy_wh |
Wh | P063 IND=11 raw |
status_code |
– | inverter state, once identified |
error_code |
– | non-zero = fault (shows the inverter as Fault) |
status_text |
– | optional human text for the code |
send() stamps each reading with the current UTC time, buffers to
unsent_readings.jsonl when the internet is down and re-sends later, and
never raises — a backend problem can't stop the polling loop.
Call send([]) even when no inverter answered. That's the heartbeat that
lets the dashboard say "inverter not responding" (site online) instead of
"datalogger offline" (site/internet down).
Trying the dashboard without the site
python fake_poller.py --url http://localhost:8090 --key change-me --backfill-days 30