The on-site agent found that the DC (P052/P054/P05A/P05C) and energy (P063) registers are static/frozen and ac_power_total_w is now computed V*I, so the backend and dashboard have to cope with those fields being absent. - Feeding/Standby from status_code (FEEDING_STATUS_CODES, default 7 and 8: INV1's OEM board uses 7). Online but not feeding = Standby; a standby inverter while peers produce is still caught by the underperformance check. Missing error_code stays "no fault". - Daily energy falls back to AC power integrated between readings, flagged estimated (≈ in the UI); out-of-order (spooled) readings recompute the day. Existing databases get the column and a rebuild on startup. - Totals are null instead of 0 when there's no energy data; lifetime shows "not available yet". Parameters the poller doesn't send are hidden on the detail page, DC lines only drawn when DC data exists. - Timestamps more than 5 min in the future are stored at receive time and counted in clamped_future — the example payload carried local Athens time labelled +00:00. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
140 lines
4.1 KiB
Python
140 lines
4.1 KiB
Python
from datetime import datetime
|
|
from typing import Any, Literal
|
|
|
|
from pydantic import BaseModel, ConfigDict, Field
|
|
|
|
InverterId = Field(min_length=1, max_length=64, pattern=r"^[A-Za-z0-9_.\-]+$")
|
|
|
|
|
|
class ReadingIn(BaseModel):
|
|
"""One inverter's values from one poll cycle.
|
|
|
|
Every parameter is optional — send what the poller could read. Unknown
|
|
keys are accepted and stored in `extra` (as are keys of an explicit
|
|
`extra` object), so new parameters can be logged before the backend
|
|
knows about them.
|
|
"""
|
|
|
|
model_config = ConfigDict(extra="allow")
|
|
|
|
inverter_id: str = InverterId
|
|
timestamp: datetime | None = Field(
|
|
default=None, description="UTC. Defaults to the time the backend receives it."
|
|
)
|
|
|
|
ac_voltage_l1_v: float | None = None
|
|
ac_voltage_l2_v: float | None = None
|
|
ac_voltage_l3_v: float | None = None
|
|
dc_voltage_mppt1_v: float | None = None
|
|
dc_voltage_mppt2_v: float | None = None
|
|
dc_current_mppt1_a: float | None = None
|
|
dc_current_mppt2_a: float | None = None
|
|
ac_current_l1_a: float | None = None
|
|
ac_current_l2_a: float | None = None
|
|
ac_current_l3_a: float | None = None
|
|
ac_power_total_w: int | None = None
|
|
grid_frequency_hz: float | None = None
|
|
temperature_c: int | None = None
|
|
daily_energy_wh: int | None = None
|
|
total_energy_wh: int | None = None
|
|
|
|
status_code: int | None = Field(default=None, description="Raw inverter state, if known")
|
|
error_code: int | None = Field(default=None, description="Non-zero = inverter reports a fault")
|
|
status_text: str | None = Field(default=None, max_length=200)
|
|
|
|
extra: dict[str, Any] | None = None
|
|
|
|
|
|
class IngestResult(BaseModel):
|
|
received: int
|
|
stored: int
|
|
duplicates: int
|
|
clamped_future: int = Field(
|
|
description="Readings stamped in the future (clock wrong, or local time sent as UTC); "
|
|
"stored at the time they were received instead"
|
|
)
|
|
|
|
|
|
class InverterUpdate(BaseModel):
|
|
name: str | None = Field(default=None, max_length=100)
|
|
capacity_kwp: float | None = Field(default=None, ge=0, le=1000)
|
|
mppt_count: int | None = Field(default=None, ge=1, le=4)
|
|
sort_order: int | None = None
|
|
notes: str | None = Field(default=None, max_length=2000)
|
|
|
|
|
|
class Inverter(BaseModel):
|
|
id: str
|
|
name: str
|
|
capacity_kwp: float | None
|
|
mppt_count: int
|
|
sort_order: int
|
|
notes: str | None
|
|
first_seen: datetime | None
|
|
last_seen: datetime | None
|
|
|
|
|
|
Severity = Literal["info", "warning", "critical"]
|
|
State = Literal["ok", "standby", "warning", "fault", "offline", "sleeping", "unknown"]
|
|
|
|
|
|
class Issue(BaseModel):
|
|
code: str
|
|
severity: Severity
|
|
message: str
|
|
|
|
|
|
class Health(BaseModel):
|
|
online: bool = Field(description="A reading arrived within ONLINE_WINDOW_SECONDS")
|
|
feeding: bool | None = Field(
|
|
description="status_code is one of FEEDING_STATUS_CODES; null when no status_code is reported"
|
|
)
|
|
state: State
|
|
issues: list[Issue]
|
|
avg_power_w: float | None = Field(description="Mean AC power over the comparison window")
|
|
relative_output: float | None = Field(
|
|
description="Output vs fleet median (1.0 = median), per kWp when capacities are set"
|
|
)
|
|
|
|
|
|
class EnergyToday(BaseModel):
|
|
wh: int | None
|
|
estimated: bool = Field(description="Integrated from AC power, not the inverter's own counter")
|
|
|
|
|
|
class InverterStatus(BaseModel):
|
|
inverter: Inverter
|
|
health: Health
|
|
energy_today: EnergyToday
|
|
latest: dict[str, Any] | None
|
|
|
|
|
|
class Totals(BaseModel):
|
|
ac_power_w: int
|
|
daily_energy_wh: int | None
|
|
daily_energy_estimated: bool
|
|
total_energy_wh: int | None = Field(description="Null until the inverters report a lifetime counter")
|
|
inverter_count: int
|
|
online_count: int
|
|
feeding_count: int
|
|
problem_count: int
|
|
|
|
|
|
class Datalogger(BaseModel):
|
|
online: bool
|
|
last_ingest_at: datetime | None
|
|
|
|
|
|
class Sun(BaseModel):
|
|
elevation: float | None
|
|
daylight: bool | None
|
|
|
|
|
|
class Summary(BaseModel):
|
|
generated_at: datetime
|
|
datalogger: Datalogger
|
|
sun: Sun
|
|
totals: Totals
|
|
fleet_median_w_per_kwp: float | None
|
|
inverters: list[InverterStatus]
|