The on-site agent found that the DC (P052/P054/P05A/P05C) and energy (P063)
registers are static/frozen and ac_power_total_w is now computed V*I, so
the backend and dashboard have to cope with those fields being absent.
- Feeding/Standby from status_code (FEEDING_STATUS_CODES, default 7 and 8:
INV1's OEM board uses 7). Online but not feeding = Standby; a standby
inverter while peers produce is still caught by the underperformance
check. Missing error_code stays "no fault".
- Daily energy falls back to AC power integrated between readings, flagged
estimated (≈ in the UI); out-of-order (spooled) readings recompute the
day. Existing databases get the column and a rebuild on startup.
- Totals are null instead of 0 when there's no energy data; lifetime shows
"not available yet". Parameters the poller doesn't send are hidden on the
detail page, DC lines only drawn when DC data exists.
- Timestamps more than 5 min in the future are stored at receive time and
counted in clamped_future — the example payload carried local Athens time
labelled +00:00.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>