- Backend /api/pos (pos_counter): session (business day, the cashier's own shift,
self-start, who can open the day), menu (sellable products with every kind of choice,
no costs; price now from the pricing engine), quote (lines by id → the waiter's
selected_options entries with DB prices → resolve_price as orders do; pos.line_invalid).
- POS device settings: default order type, start category, receipt printer (new ref
sources categories / printers, also in the manager's Devices dialogs).
- Terminal apps/pos: shift gate (start shift with drawer cash), categories, search,
product grid, price check, options dialog, cart priced by the backend.
- Tests: backend test_pos (13), terminal pos.test.mjs, manager refOptions,
terminal.mjs +10 POS checks.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- order_items.claimed_by / claimed_at (Alembic 0015). POST/DELETE
/api/kds/orders/{id}/items/{item}/claim (kds.bump): someone else's claim is refused
(kds.item_claimed), letting go works for anyone with kds.bump; live kds_item_claimed.
In progress claims for whoever did it; done/served/pending/declined clear the claim.
- Fix: order-level status and decline from a zone screen changed every zone's items;
now only the screen's zone, and a zone screen sees the order status of its own items.
- Terminal: "I'm on it" / "Let go" on the selected card, the cook's name on claimed items.
- Tests: backend +6, terminal unit +1, terminal.mjs +6 with a second screen and cook.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- WebSocket: credentials may come in the first frame ({cursor, token?, device?}).
A device token alone connects a paired screen (login-none apps get every event, a
sign-in app only events addressed to it); a terminal session's JWT needs its own
device, as over HTTP. Refusals send {type: refused, data: {code}} + close 4001/4003.
- ws_bus: registry of open sockets by user, session and device. Ending a session
closes its sockets (session.ended); revoke/reassign close the device's sockets
(device.revoked / device.updated); edits and module on/off send device.updated.
Events can target devices (device_ids=..., sync_events.target_device_ids, rev 0014).
Pushes go through each socket's own loop (call_soon_threadsafe).
- Device config: DeviceApp.config = typed ConfigFields, validated on pair/edit/
reassign (validation.device_config), effective values (defaults filled) in both
device views and the module catalogue. First field: auto_sign_out_minutes (KDS, POS).
- Manager: DeviceConfigFields renders an app's fields in the pair and edit dialogs.
- @xenia/api createLiveClient: `credentials` and `onRefused` options.
- Tests: tests/test_live.py (11), module texts for config fields, live client,
devices logic, manager.mjs device setting + live socket checks.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- Bell in the header: /api/platform/notifications with unread count, live via
the new LiveProvider (one createLiveClient connection) on platform_notification
and reconnect; mark read / all; warning+critical pop a toast.
- Settings: Sign-in card (manager/waiter/device modes, require username, one
session per manager/waiter, username autofill) replaces the dead v1
security.login_method card; new "Venue & language" tab (language, time zone);
print alert threshold in Printing. Tab labels are i18n keys.
- Technical > Log files: list + download of the daily logs (owner-level).
Backend: GET /api/system/logs, /api/system/logs/{date} (core.settings.manage),
error system.log_not_found.
- Setup wizard asks staff language and time zone (setup/init stores them).
- @xenia/ui theme helpers (applyTheme, getStoredTheme); the manager stays light
until phase 6 converts the older pages (owner decision 2026-11-14).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Platform-v2 step 2.6b:
- backend: POST /api/auth/unlock {pin|password} checks the CURRENT session's
user and keeps the session (no new login/token); 5 wrong tries end it
(auth.wrong_pin with attempts_left, then auth.session_ended); bootstrap
gains `login` (manager_mode, autofill_username, support)
- manager LoginPage rewritten on @xenia/ui + i18n: client "manager", password
or PIN pad per setting, remembered/only account card, support access panel
(challenge -> code -> 4 h session, not remembered as an account), notice
when the license runs the free tier (expired/inactive/locked/clock/unverified)
- lock screen on /api/auth/unlock with the shared PinPad
- @xenia/ui PinPad: variable length (minLength/maxLength, OK key, Enter)
- e2e manager.mjs: 33 checks (+ lockout after 5 wrong PINs, PIN login mode,
support access with a wrong then right code)
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Platform-v2 step 2.5 (APPS_PLATFORM D-7, D-10, §9):
- @xenia/api: createApiClient (app passes its axios; session/device headers,
err.xenia codes, 401/offline hooks, manager-override retry: ask PIN, grant,
retry once with X-Xenia-Override); errorMessage; createLiveClient = the
waiter's WebSocket logic (cursor replay, backoff, online) moved unchanged
- @xenia/access: AccessProvider (bootstrap per session token, language +
venue formats, translated ui labels, approval dialog), useAccess/useCan/
useModule, Can, RequireModule
- i18n: errors namespace for every backend code (en/el, test vs core/errors.py),
override/access texts
- manager: client from createApiClient, AccessProvider in a layout route,
/kds behind RequireModule, usePermissions from bootstrap keys; login and
unlock no longer treat a wrong password/PIN as "session ended" (a wrong
lock-screen PIN used to log the manager out)
- waiter: useWebSocket is a thin wrapper over createLiveClient
- tests: api/access unit tests; new e2e suite tests/e2e/manager.mjs; CS-18
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>