bonaminandClaude Opus 5.5 d4b584e364 feat: solar inverter monitor — FastAPI + SQLite backend, React PWA dashboard
Monitoring for the Refusol 020K inverters. The on-site poller POSTs each
60 s cycle to /api/readings; the dashboard answers first whether every
inverter is operating and whether one is producing far less than its peers
(string fuse / breaker problems).

- Backend: FastAPI + SQLite. Parameters defined once in fields.py (columns
  auto-added on start); unknown poller keys are kept in `extra` since the
  parameter map is still being researched. Idempotent ingest, daily energy
  rollup in site-local days, history downsampling, 2-year retention.
- Health: Offline vs Sleeping (sun elevation) vs No data (datalogger
  silent, detected via empty-batch heartbeats), Fault from error_code,
  underperformance vs fleet median (per kWp when sizes set), MPPT imbalance.
- Frontend: mobile-first React + Tailwind, installable PWA, comparison bars,
  24 h power / 30 day energy charts, detail page with all parameters.
- Docker: backend + frontend + nginx on one port for NPM, as in
  bellsystems-cp; deploy-host.sh pulls main and rebuilds.
- poller/backend_client.py: stdlib client with offline spool for
  refusol_poller.py; fake_poller.py simulates the site.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-21 07:42:48 +03:00

40 lines
1.6 KiB
Bash

# Host port the nginx container binds; point NPM (solar.bonamin.net) at it
HTTP_PORT=8090
# Shared secret: the on-site poller sends it as X-API-Key on POST /api/readings,
# and the dashboard asks for it when editing inverter settings.
# Generate one with: python -c "import secrets; print(secrets.token_urlsafe(32))"
API_KEY=change-me
# Site location — local day boundaries for daily energy, and the sun's
# elevation so inverters that switch off at night show "Sleeping", not "Offline".
# Leave LATITUDE/LONGITUDE empty to treat every silent inverter as offline.
SITE_TIMEZONE=Europe/Athens
SITE_LATITUDE=
SITE_LONGITUDE=
# Sun elevation (degrees) below which inverters are expected to be off
DAYLIGHT_MIN_ELEVATION=5
# Inverter counts as Online if its last reading is newer than this
ONLINE_WINDOW_SECONDS=300
# Raw readings older than this are purged (daily energy totals are kept)
RETENTION_DAYS=730
# Underperformance alarm: flag an inverter producing less than this fraction
# of the fleet median, averaged over the window. Skipped while the fleet makes
# less than the minimum (dawn/dusk/heavy cloud). The per-kWp minimum is used
# once every inverter has its array size (kWp) set, the W minimum otherwise.
UNDERPERFORM_RATIO=0.75
UNDERPERFORM_WINDOW_SECONDS=600
UNDERPERFORM_MIN_FLEET_W_PER_KWP=50
UNDERPERFORM_MIN_FLEET_W=1000
# String alarm: one MPPT input below this fraction of the other, once the
# stronger input exceeds MPPT_MIN_POWER_W (inverters set to 2 MPPTs only)
MPPT_IMBALANCE_RATIO=0.5
MPPT_MIN_POWER_W=1000
# Browser origins allowed to call the API directly (JSON list). The dashboard
# itself is same-origin and doesn't need this.
CORS_ORIGINS=["*"]