bonaminandClaude Opus 5.5 d01cef991f feat: match the verified on-site poller payload
The on-site agent found that the DC (P052/P054/P05A/P05C) and energy (P063)
registers are static/frozen and ac_power_total_w is now computed V*I, so
the backend and dashboard have to cope with those fields being absent.

- Feeding/Standby from status_code (FEEDING_STATUS_CODES, default 7 and 8:
  INV1's OEM board uses 7). Online but not feeding = Standby; a standby
  inverter while peers produce is still caught by the underperformance
  check. Missing error_code stays "no fault".
- Daily energy falls back to AC power integrated between readings, flagged
  estimated (≈ in the UI); out-of-order (spooled) readings recompute the
  day. Existing databases get the column and a rebuild on startup.
- Totals are null instead of 0 when there's no energy data; lifetime shows
  "not available yet". Parameters the poller doesn't send are hidden on the
  detail page, DC lines only drawn when DC data exists.
- Timestamps more than 5 min in the future are stored at receive time and
  counted in clamped_future — the example payload carried local Athens time
  labelled +00:00.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-21 09:43:55 +03:00

71 lines
2.7 KiB
Python

from functools import lru_cache
from pydantic import field_validator
from pydantic_settings import BaseSettings, SettingsConfigDict
class Settings(BaseSettings):
model_config = SettingsConfigDict(env_file=".env", extra="ignore")
# Shared secret the on-site poller sends in X-API-Key. Also guards the
# inverter metadata edits (name, kWp, ...).
api_key: str = "change-me"
db_path: str = "/app/data/solar.db"
# Local calendar of the installation — decides where "today" starts for
# the daily-energy rollup and the charts.
site_timezone: str = "Europe/Athens"
# Used to compute the sun's elevation so an inverter that went quiet at
# night shows as "sleeping" instead of raising an alarm. Leave empty to
# treat every silent inverter as offline.
site_latitude: float | None = None
site_longitude: float | None = None
# Below this sun elevation (degrees) inverters are expected to be off.
daylight_min_elevation: float = 5.0
# A reading newer than this marks an inverter as Online.
online_window_seconds: int = 300
retention_days: int = 730
# Underperformance check: an inverter is flagged when its output (per kWp
# if capacities are set, otherwise raw W) is below this fraction of the
# fleet median over the last few minutes.
underperform_ratio: float = 0.75
underperform_window_seconds: int = 600
# Skip the check while the fleet is barely producing (dawn, dusk, heavy
# overcast) — differences there are noise.
underperform_min_fleet_w_per_kwp: float = 50.0
underperform_min_fleet_w: float = 1000.0
# One MPPT producing under this fraction of the other is flagged (only
# for inverters with mppt_count = 2), once the stronger one exceeds
# mppt_min_power_w.
mppt_imbalance_ratio: float = 0.5
mppt_min_power_w: float = 1000.0
# status_code values that mean the inverter is feeding the grid
# (8 on the standard units, 7 on the OEM board in INV1). Any other
# reported code shows as Standby.
feeding_status_codes: list[int] = [7, 8]
# Readings stamped further than this in the future (wrong clock or local
# time sent as UTC) are stored at the time they were received instead.
max_future_skew_seconds: int = 300
# Energy is estimated by integrating AC power between consecutive
# readings; gaps longer than this are not bridged.
energy_integration_max_gap_seconds: int = 300
cors_origins: list[str] = ["*"]
@field_validator("site_latitude", "site_longitude", mode="before")
@classmethod
def blank_is_none(cls, v):
return None if isinstance(v, str) and not v.strip() else v
@lru_cache
def get_settings() -> Settings:
return Settings()