The on-site agent found that the DC (P052/P054/P05A/P05C) and energy (P063) registers are static/frozen and ac_power_total_w is now computed V*I, so the backend and dashboard have to cope with those fields being absent. - Feeding/Standby from status_code (FEEDING_STATUS_CODES, default 7 and 8: INV1's OEM board uses 7). Online but not feeding = Standby; a standby inverter while peers produce is still caught by the underperformance check. Missing error_code stays "no fault". - Daily energy falls back to AC power integrated between readings, flagged estimated (≈ in the UI); out-of-order (spooled) readings recompute the day. Existing databases get the column and a rebuild on startup. - Totals are null instead of 0 when there's no energy data; lifetime shows "not available yet". Parameters the poller doesn't send are hidden on the detail page, DC lines only drawn when DC data exists. - Timestamps more than 5 min in the future are stored at receive time and counted in clamped_future — the example payload carried local Athens time labelled +00:00. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
71 lines
2.7 KiB
Python
71 lines
2.7 KiB
Python
from functools import lru_cache
|
|
|
|
from pydantic import field_validator
|
|
from pydantic_settings import BaseSettings, SettingsConfigDict
|
|
|
|
|
|
class Settings(BaseSettings):
|
|
model_config = SettingsConfigDict(env_file=".env", extra="ignore")
|
|
|
|
# Shared secret the on-site poller sends in X-API-Key. Also guards the
|
|
# inverter metadata edits (name, kWp, ...).
|
|
api_key: str = "change-me"
|
|
|
|
db_path: str = "/app/data/solar.db"
|
|
|
|
# Local calendar of the installation — decides where "today" starts for
|
|
# the daily-energy rollup and the charts.
|
|
site_timezone: str = "Europe/Athens"
|
|
# Used to compute the sun's elevation so an inverter that went quiet at
|
|
# night shows as "sleeping" instead of raising an alarm. Leave empty to
|
|
# treat every silent inverter as offline.
|
|
site_latitude: float | None = None
|
|
site_longitude: float | None = None
|
|
# Below this sun elevation (degrees) inverters are expected to be off.
|
|
daylight_min_elevation: float = 5.0
|
|
|
|
# A reading newer than this marks an inverter as Online.
|
|
online_window_seconds: int = 300
|
|
retention_days: int = 730
|
|
|
|
# Underperformance check: an inverter is flagged when its output (per kWp
|
|
# if capacities are set, otherwise raw W) is below this fraction of the
|
|
# fleet median over the last few minutes.
|
|
underperform_ratio: float = 0.75
|
|
underperform_window_seconds: int = 600
|
|
# Skip the check while the fleet is barely producing (dawn, dusk, heavy
|
|
# overcast) — differences there are noise.
|
|
underperform_min_fleet_w_per_kwp: float = 50.0
|
|
underperform_min_fleet_w: float = 1000.0
|
|
|
|
# One MPPT producing under this fraction of the other is flagged (only
|
|
# for inverters with mppt_count = 2), once the stronger one exceeds
|
|
# mppt_min_power_w.
|
|
mppt_imbalance_ratio: float = 0.5
|
|
mppt_min_power_w: float = 1000.0
|
|
|
|
# status_code values that mean the inverter is feeding the grid
|
|
# (8 on the standard units, 7 on the OEM board in INV1). Any other
|
|
# reported code shows as Standby.
|
|
feeding_status_codes: list[int] = [7, 8]
|
|
|
|
# Readings stamped further than this in the future (wrong clock or local
|
|
# time sent as UTC) are stored at the time they were received instead.
|
|
max_future_skew_seconds: int = 300
|
|
|
|
# Energy is estimated by integrating AC power between consecutive
|
|
# readings; gaps longer than this are not bridged.
|
|
energy_integration_max_gap_seconds: int = 300
|
|
|
|
cors_origins: list[str] = ["*"]
|
|
|
|
@field_validator("site_latitude", "site_longitude", mode="before")
|
|
@classmethod
|
|
def blank_is_none(cls, v):
|
|
return None if isinstance(v, str) and not v.strip() else v
|
|
|
|
|
|
@lru_cache
|
|
def get_settings() -> Settings:
|
|
return Settings()
|