FastAPI runs a sync dependency's setup, the endpoint and the teardown on
whichever threadpool worker is free, so a connection opened on one thread
was used/closed on another and sqlite3 raised ProgrammingError — 500s on
/api/power, /api/energy/daily and /api/summary under concurrent requests
(the dashboard fires three at once). Each request still gets its own
connection, used by one thread at a time.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
P06D is a latched 21450 (not power), P052/P05A static, P063 frozen; power
is computed V*I. Lists what's sent, what isn't, the unmapped diagnostics,
the INV1-INV5 IP assignments, and that timestamps must be real UTC. The
simulator now sends the same payload shape.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The on-site agent found that the DC (P052/P054/P05A/P05C) and energy (P063)
registers are static/frozen and ac_power_total_w is now computed V*I, so
the backend and dashboard have to cope with those fields being absent.
- Feeding/Standby from status_code (FEEDING_STATUS_CODES, default 7 and 8:
INV1's OEM board uses 7). Online but not feeding = Standby; a standby
inverter while peers produce is still caught by the underperformance
check. Missing error_code stays "no fault".
- Daily energy falls back to AC power integrated between readings, flagged
estimated (≈ in the UI); out-of-order (spooled) readings recompute the
day. Existing databases get the column and a rebuild on startup.
- Totals are null instead of 0 when there's no energy data; lifetime shows
"not available yet". Parameters the poller doesn't send are hidden on the
detail page, DC lines only drawn when DC data exists.
- Timestamps more than 5 min in the future are stored at receive time and
counted in clamped_future — the example payload carried local Athens time
labelled +00:00.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The hard-coded /home/bonamin/refusol-datalogger didn't match the real
clone (repo is refusol-datalogging). README clone URL updated too.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Monitoring for the Refusol 020K inverters. The on-site poller POSTs each
60 s cycle to /api/readings; the dashboard answers first whether every
inverter is operating and whether one is producing far less than its peers
(string fuse / breaker problems).
- Backend: FastAPI + SQLite. Parameters defined once in fields.py (columns
auto-added on start); unknown poller keys are kept in `extra` since the
parameter map is still being researched. Idempotent ingest, daily energy
rollup in site-local days, history downsampling, 2-year retention.
- Health: Offline vs Sleeping (sun elevation) vs No data (datalogger
silent, detected via empty-batch heartbeats), Fault from error_code,
underperformance vs fleet median (per kWp when sizes set), MPPT imbalance.
- Frontend: mobile-first React + Tailwind, installable PWA, comparison bars,
24 h power / 30 day energy charts, detail page with all parameters.
- Docker: backend + frontend + nginx on one port for NPM, as in
bellsystems-cp; deploy-host.sh pulls main and rebuilds.
- poller/backend_client.py: stdlib client with offline spool for
refusol_poller.py; fake_poller.py simulates the site.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>