docs: settings API, per-inverter offline window, language
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -70,9 +70,11 @@ generate a Flutter client later).
|
||||
| `GET` | `/api/inverters/{id}/latest` | Latest reading (plus derived DC power / efficiency) |
|
||||
| `GET` | `/api/inverters/{id}/history` | `from`, `to` (ISO), optional `bucket` seconds, `field` (repeatable). Downsampled to ≤600 points |
|
||||
| `GET` | `/api/inverters/{id}/daily` | Energy + peak power per local day (`days`, default 365, or `from`/`to` dates) |
|
||||
| `GET` | `/api/power` | AC power of all inverters over time (default 24 h) |
|
||||
| `GET` | `/api/power` | AC power of all inverters over time (default 24 h; `last_run=true` = since the inverters last woke up) |
|
||||
| `GET` | `/api/energy/daily` | Energy per day per inverter + total (default 30 days) |
|
||||
| `GET` | `/api/meta/fields` | Label / unit / group of every parameter — render from this |
|
||||
| `GET` | `/api/settings` | Dashboard display options (comparison averaging / scale / reference, power chart range / smoothing, voltage display, default language) |
|
||||
| `PUT` | `/api/settings` | Replace them — applies to every viewer (no accounts). `X-API-Key` required |
|
||||
|
||||
### Adding parameters
|
||||
|
||||
@@ -84,8 +86,10 @@ the chart picker without further changes.
|
||||
|
||||
### Health rules
|
||||
|
||||
- **Offline** — no reading for `ONLINE_WINDOW_SECONDS` (5 min) while the
|
||||
datalogger is still posting and the sun is up. At night that's **Sleeping**;
|
||||
- **Offline** — no reading for `ONLINE_WINDOW_SECONDS` (5 min) — or 2.5× the
|
||||
inverter's own reporting interval if that is longer (INV5 comes from the
|
||||
cloud every ~5 min → ~12 min) — while the datalogger is still posting and
|
||||
the sun is up. At night that's **Sleeping**;
|
||||
if the datalogger itself is silent the state is **No data** (and a banner
|
||||
says so).
|
||||
- **Fault** — the reading carries a non-zero `error_code`. No `error_code`
|
||||
@@ -104,10 +108,19 @@ Thresholds are in `.env`.
|
||||
|
||||
Daily energy uses, in order: the inverter's daily counter
|
||||
(`daily_energy_wh`), the growth of its lifetime counter, or — while neither
|
||||
is decoded, which is the case today — AC power integrated over time
|
||||
(trapezoid between consecutive readings, gaps over 5 min not bridged). The
|
||||
estimate is flagged (`estimated: true` in the API, "≈" on the dashboard).
|
||||
Lifetime energy shows "not available yet" until `total_energy_wh` is sent.
|
||||
is sent (INV1–INV4 today; only INV5 has real counters) — AC power
|
||||
integrated over time (trapezoid between consecutive readings, gaps over 5 min
|
||||
not bridged). The estimate is flagged (`estimated: true` in the API, "≈" on
|
||||
the dashboard). Lifetime energy only exists where `total_energy_wh` is sent;
|
||||
the dashboard total says how many inverters it covers.
|
||||
|
||||
### Dashboard settings and language
|
||||
|
||||
The ⚙ page sets the display options above for everyone; the API key is asked
|
||||
once and remembered on the device. The language (Greek / English) can be
|
||||
switched per device from the header; devices that haven't picked one use the
|
||||
shared default. Issue texts are translated client-side from each issue's
|
||||
`code` + `params`, so new clients (Flutter) can do the same.
|
||||
|
||||
The current state of the register map is in `poller/README.md`.
|
||||
|
||||
|
||||