docs: record the verified register map and inverter IDs

P06D is a latched 21450 (not power), P052/P05A static, P063 frozen; power
is computed V*I. Lists what's sent, what isn't, the unmapped diagnostics,
the INV1-INV5 IP assignments, and that timestamps must be real UTC. The
simulator now sends the same payload shape.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
2026-10-21 09:43:56 +03:00
co-authored by Claude Opus 5.5
parent d01cef991f
commit 42c7d18207
4 changed files with 80 additions and 55 deletions
+17 -1
View File
@@ -88,13 +88,29 @@ the chart picker without further changes.
datalogger is still posting and the sun is up. At night that's **Sleeping**;
if the datalogger itself is silent the state is **No data** (and a banner
says so).
- **Fault** — the reading carries a non-zero `error_code`.
- **Fault** — the reading carries a non-zero `error_code`. No `error_code`
(the poller doesn't send one yet) means no fault.
- **Feeding / Standby** — online and `status_code` is in
`FEEDING_STATUS_CODES` (7, 8) → Feeding; any other code → Standby. An
inverter in standby while its peers produce is caught by the
underperformance check below.
- **Check needed** — output below `UNDERPERFORM_RATIO` (75%) of the fleet
median over the last 10 min (per kWp once every inverter has its array size
set), or one MPPT input below half of the other.
Thresholds are in `.env`.
### Energy
Daily energy uses, in order: the inverter's daily counter
(`daily_energy_wh`), the growth of its lifetime counter, or — while neither
is decoded, which is the case today — AC power integrated over time
(trapezoid between consecutive readings, gaps over 5 min not bridged). The
estimate is flagged (`estimated: true` in the API, "≈" on the dashboard).
Lifetime energy shows "not available yet" until `total_energy_wh` is sent.
The current state of the register map is in `poller/README.md`.
## Data retention
Raw readings older than `RETENTION_DAYS` (730) are purged every 6 h. The
+5 -4
View File
@@ -11,7 +11,8 @@ the on-site side: read the inverters, POST the values.
use it to send. It's standard library only. It timestamps readings, keeps
them in `unsent_readings.jsonl` when the internet is down, re-sends them
later, and never raises.
- `README.md` (next to this brief): the field names, units and scalings.
- `README.md` (next to this brief): the field names, units and the current
state of the register map (what's verified, what isn't sent yet).
## What to do every 60 s
@@ -44,9 +45,9 @@ while True:
e.g. `INV1`..`INV5` matching labels on the units. It's the database key.
Pretty names are set later in the dashboard, not here. Allowed characters:
letters, digits, `_ . -`.
3. **Send converted values**, not raw ones, using the keys and scalings in
`README.md` (e.g. `ac_voltage_l1_v` = P050 raw / 40). Leave out anything
you couldn't read; every field is optional.
3. **Send converted values**, not raw ones, using the keys in `README.md`.
Leave out anything you couldn't read or haven't verified; every field is
optional. Timestamps must be real UTC (see README).
4. **New or unconfirmed parameters:** send them too, under a descriptive key
(e.g. `p0xx_raw`). The backend stores unknown keys and shows them on the
inverter page under "Other (unmapped)". Tell the owner when a mapping is
+32 -15
View File
@@ -1,6 +1,6 @@
# On-site poller
`refusol_poller.py` (not in this repo yet) reads the inverters over USS/TCP
`refusol_poller.py` (lives on the site laptop, not in this repo) reads the inverters over USS/TCP
(port 21062, USS address 0). It sends each cycle to the backend through
`backend_client.py` — copy that file next to the poller.
@@ -30,20 +30,37 @@ Each dict uses the keys below (all optional — send what was read). Anything
else you include (e.g. a newly discovered parameter as `"p0xx_raw": 1234`) is
stored too and shows under "Other (unmapped)" on the inverter page.
| key | unit | source |
|---|---|---|
| `ac_voltage_l1_v` / `_l2_v` / `_l3_v` | V | P050 / P05B / P064 raw / 40 |
| `dc_voltage_mppt1_v` / `_mppt2_v` | V | P052 / P054 raw / 40 |
| `dc_current_mppt1_a` / `_mppt2_a` | A | P05A / P05C raw / 10 |
| `ac_current_l1_a` / `_l2_a` / `_l3_a` | A | P068 / P069 / P06A raw / 100 |
| `ac_power_total_w` | W | P06D raw |
| `grid_frequency_hz` | Hz | P06C raw / 20 |
| `temperature_c` | °C | P070 raw >> 16 |
| `daily_energy_wh` | Wh | P063 IND=0 raw × 10 |
| `total_energy_wh` | Wh | P063 IND=11 raw |
| `status_code` | – | inverter state, once identified |
| `error_code` | – | non-zero = fault (shows the inverter as **Fault**) |
| `status_text` | – | optional human text for the code |
State of the map as verified on site (2026-10-21):
| key | unit | status | source |
|---|---|---|---|
| `ac_power_total_w` | W | ✅ sent | **Computed** by the poller: Σ (phase V × phase I), forced to 0 when the inverter isn't feeding. *Not* P06D — P06D sits latched at 21450 on any feeding unit (nameplate/limit, not live power). |
| `ac_voltage_l1_v` / `_l2_v` / `_l3_v` | V | ✅ sent | P050 / P05B / P064 raw / 40 |
| `ac_current_l1_a` / `_l2_a` / `_l3_a` | A | ✅ sent | P068 / P069 / P06A raw / 100 |
| `grid_frequency_hz` | Hz | ✅ sent | P06C raw / 20 |
| `temperature_c` | °C | ✅ sent | P070 raw >> 16 |
| `status_code` | – | ✅ sent | PZD status word. **7 and 8 = feeding** (7 on INV1's OEM board, 8 on the standard units); anything else shows as Standby. Other values not decoded yet. |
| `status_text` | – | ✅ sent | `"feeding"` / `"standby/not feeding"` |
| `dc_voltage_mppt1_v` / `_mppt2_v` | V | ❌ not sent | P052 / P054 are static nameplate/limit values, not live. Real registers TBD. |
| `dc_current_mppt1_a` / `_mppt2_a` | A | ❌ not sent | P05A / P05C likewise static. Real registers TBD. |
| `daily_energy_wh` | Wh | ❌ not sent | P063 IND=0 is frozen, not accumulating. Real register TBD. Until then the backend **estimates** daily energy by integrating `ac_power_total_w` (shown with ≈). |
| `total_energy_wh` | Wh | ❌ not sent | P063 IND=11 decode wrong. Real register TBD. Lifetime shows "not available yet". |
| `error_code` | – | ❌ not sent | No fault register confirmed yet. Absent = no fault. Non-zero will show the inverter as **Fault**. |
Unmapped diagnostics currently sent (stored, shown under "Other (unmapped)",
never treated as telemetry): `p06d_raw_latched`, `p052_static_v`,
`p05a_static_a`, `p063_ind0_raw`.
Inverter IDs (permanent database keys): INV1 = 192.168.1.11, INV2 =
192.168.1.12, INV3 = 192.168.1.13 (reserved, not connected yet), INV4 =
192.168.1.221, INV5 = REFUsol 20K-3T (reserved, no read path yet). An
inverter appears on the dashboard the first time it reports.
**Timestamps must be UTC.** Send them with the right offset (e.g.
`datetime.now(timezone.utc).isoformat()`), or leave `timestamp` out and let
`backend_client.py` add it. A reading stamped more than 5 min in the future
(e.g. local Athens time labelled `+00:00`) is stored at the time it was
received instead, and the response's `clamped_future` count says so.
`send()` stamps each reading with the current UTC time, buffers to
`unsent_readings.jsonl` when the internet is down and re-sends later, and
+26 -35
View File
@@ -2,9 +2,11 @@
python fake_poller.py --url http://localhost:8090 --key change-me --backfill-days 30
--backfill-days first loads that many days of history (one reading per
5 minutes), then it posts live readings every --interval seconds. Inverter
INV3 runs with a dead MPPT2 string so the warnings show up.
Sends what the real poller sends today (AC side, temperature, status code,
unmapped diagnostics; no DC or energy counters). --backfill-days first loads
that many days of history (one reading per 5 minutes), then it posts live
readings every --interval seconds. INV4 runs at half output (as if a string
fuse had blown) so the warnings show up.
"""
import argparse
@@ -15,7 +17,7 @@ from datetime import datetime, timedelta, timezone
from backend_client import BackendClient
INVERTERS = ["INV1", "INV2", "INV3", "INV4", "INV5"]
INVERTERS = ["INV1", "INV2", "INV4"]
PEAK_W = 18_000
@@ -26,40 +28,32 @@ def sun_factor(t: datetime) -> float:
return max(0.0, math.sin(math.pi * x)) if 0 < x < 1 else 0.0
def reading(inv: str, t: datetime, state: dict) -> dict | None:
def reading(inv: str, t: datetime) -> dict | None:
f = sun_factor(t) * random.uniform(0.93, 1.0)
if f <= 0.01:
return None # inverter asleep at night, doesn't answer
dead_mppt2 = inv == "INV3"
p_dc1 = PEAK_W / 2 * f
p_dc2 = 0 if dead_mppt2 else PEAK_W / 2 * f
v1, v2 = 560 + 60 * f, 560 + 60 * f
ac = int((p_dc1 + p_dc2) * 0.97)
day = t.date()
if state.get((inv, "day")) != day:
state[(inv, "day")] = day
state[(inv, "daily")] = 0
state[(inv, "daily")] += ac * state["step"] / 3600
state[(inv, "total")] = state.get((inv, "total"), 40_000_000) + ac * state["step"] / 3600
i_ac = ac / 3 / 230
feeding = f > 0.03
w = int(PEAK_W * f * (0.5 if inv == "INV4" else 1.0)) if feeding else 0
volts = [round(random.uniform(229, 236), 2) for _ in range(3)]
amps = [round(w / 3 / v, 2) for v in volts]
return {
"inverter_id": inv,
"timestamp": t.isoformat(timespec="seconds"),
"ac_voltage_l1_v": round(random.uniform(228, 236), 1),
"ac_voltage_l2_v": round(random.uniform(228, 236), 1),
"ac_voltage_l3_v": round(random.uniform(228, 236), 1),
"dc_voltage_mppt1_v": round(v1, 1),
"dc_voltage_mppt2_v": round(v2 if not dead_mppt2 else 30.0, 1),
"dc_current_mppt1_a": round(p_dc1 / v1, 1),
"dc_current_mppt2_a": round(p_dc2 / v2, 1),
"ac_current_l1_a": round(i_ac, 2),
"ac_current_l2_a": round(i_ac, 2),
"ac_current_l3_a": round(i_ac, 2),
"ac_power_total_w": ac,
"ac_voltage_l1_v": volts[0],
"ac_voltage_l2_v": volts[1],
"ac_voltage_l3_v": volts[2],
"ac_current_l1_a": amps[0],
"ac_current_l2_a": amps[1],
"ac_current_l3_a": amps[2],
"ac_power_total_w": w,
"grid_frequency_hz": round(random.uniform(49.95, 50.05), 2),
"temperature_c": int(30 + 25 * f),
"daily_energy_wh": int(state[(inv, "daily")] // 10 * 10),
"total_energy_wh": int(state[(inv, "total")]),
"status_code": (7 if inv == "INV1" else 8) if feeding else 3,
"status_text": "feeding" if feeding else "standby/not feeding",
"p06d_raw_latched": 21450,
"p052_static_v": 312.5,
"p05a_static_a": 45.0,
"p063_ind0_raw": 1872,
}
@@ -72,13 +66,11 @@ def main() -> None:
args = ap.parse_args()
client = BackendClient(args.url, args.key, spool_path="fake_unsent.jsonl")
state: dict = {}
if args.backfill_days:
state["step"] = 300
t = datetime.now(timezone.utc) - timedelta(days=args.backfill_days)
batch: list[dict] = []
while t < datetime.now(timezone.utc):
batch += [r for inv in INVERTERS if (r := reading(inv, t, state))]
batch += [r for inv in INVERTERS if (r := reading(inv, t))]
if len(batch) >= 1000:
client.send(batch)
batch = []
@@ -86,10 +78,9 @@ def main() -> None:
client.send(batch)
print(f"Backfilled {args.backfill_days} days")
state["step"] = args.interval
while True:
now = datetime.now(timezone.utc)
batch = [r for inv in INVERTERS if (r := reading(inv, now, state))]
batch = [r for inv in INVERTERS if (r := reading(inv, now))]
ok = client.send(batch)
print(f"{now:%H:%M:%S} sent {len(batch)} readings, ok={ok}")
time.sleep(args.interval)