docs: record the verified register map and inverter IDs

P06D is a latched 21450 (not power), P052/P05A static, P063 frozen; power
is computed V*I. Lists what's sent, what isn't, the unmapped diagnostics,
the INV1-INV5 IP assignments, and that timestamps must be real UTC. The
simulator now sends the same payload shape.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
2026-10-21 09:43:56 +03:00
co-authored by Claude Opus 5.5
parent d01cef991f
commit 42c7d18207
4 changed files with 80 additions and 55 deletions
+17 -1
View File
@@ -88,13 +88,29 @@ the chart picker without further changes.
datalogger is still posting and the sun is up. At night that's **Sleeping**; datalogger is still posting and the sun is up. At night that's **Sleeping**;
if the datalogger itself is silent the state is **No data** (and a banner if the datalogger itself is silent the state is **No data** (and a banner
says so). says so).
- **Fault** — the reading carries a non-zero `error_code`. - **Fault** — the reading carries a non-zero `error_code`. No `error_code`
(the poller doesn't send one yet) means no fault.
- **Feeding / Standby** — online and `status_code` is in
`FEEDING_STATUS_CODES` (7, 8) → Feeding; any other code → Standby. An
inverter in standby while its peers produce is caught by the
underperformance check below.
- **Check needed** — output below `UNDERPERFORM_RATIO` (75%) of the fleet - **Check needed** — output below `UNDERPERFORM_RATIO` (75%) of the fleet
median over the last 10 min (per kWp once every inverter has its array size median over the last 10 min (per kWp once every inverter has its array size
set), or one MPPT input below half of the other. set), or one MPPT input below half of the other.
Thresholds are in `.env`. Thresholds are in `.env`.
### Energy
Daily energy uses, in order: the inverter's daily counter
(`daily_energy_wh`), the growth of its lifetime counter, or — while neither
is decoded, which is the case today — AC power integrated over time
(trapezoid between consecutive readings, gaps over 5 min not bridged). The
estimate is flagged (`estimated: true` in the API, "≈" on the dashboard).
Lifetime energy shows "not available yet" until `total_energy_wh` is sent.
The current state of the register map is in `poller/README.md`.
## Data retention ## Data retention
Raw readings older than `RETENTION_DAYS` (730) are purged every 6 h. The Raw readings older than `RETENTION_DAYS` (730) are purged every 6 h. The
+5 -4
View File
@@ -11,7 +11,8 @@ the on-site side: read the inverters, POST the values.
use it to send. It's standard library only. It timestamps readings, keeps use it to send. It's standard library only. It timestamps readings, keeps
them in `unsent_readings.jsonl` when the internet is down, re-sends them them in `unsent_readings.jsonl` when the internet is down, re-sends them
later, and never raises. later, and never raises.
- `README.md` (next to this brief): the field names, units and scalings. - `README.md` (next to this brief): the field names, units and the current
state of the register map (what's verified, what isn't sent yet).
## What to do every 60 s ## What to do every 60 s
@@ -44,9 +45,9 @@ while True:
e.g. `INV1`..`INV5` matching labels on the units. It's the database key. e.g. `INV1`..`INV5` matching labels on the units. It's the database key.
Pretty names are set later in the dashboard, not here. Allowed characters: Pretty names are set later in the dashboard, not here. Allowed characters:
letters, digits, `_ . -`. letters, digits, `_ . -`.
3. **Send converted values**, not raw ones, using the keys and scalings in 3. **Send converted values**, not raw ones, using the keys in `README.md`.
`README.md` (e.g. `ac_voltage_l1_v` = P050 raw / 40). Leave out anything Leave out anything you couldn't read or haven't verified; every field is
you couldn't read; every field is optional. optional. Timestamps must be real UTC (see README).
4. **New or unconfirmed parameters:** send them too, under a descriptive key 4. **New or unconfirmed parameters:** send them too, under a descriptive key
(e.g. `p0xx_raw`). The backend stores unknown keys and shows them on the (e.g. `p0xx_raw`). The backend stores unknown keys and shows them on the
inverter page under "Other (unmapped)". Tell the owner when a mapping is inverter page under "Other (unmapped)". Tell the owner when a mapping is
+32 -15
View File
@@ -1,6 +1,6 @@
# On-site poller # On-site poller
`refusol_poller.py` (not in this repo yet) reads the inverters over USS/TCP `refusol_poller.py` (lives on the site laptop, not in this repo) reads the inverters over USS/TCP
(port 21062, USS address 0). It sends each cycle to the backend through (port 21062, USS address 0). It sends each cycle to the backend through
`backend_client.py` — copy that file next to the poller. `backend_client.py` — copy that file next to the poller.
@@ -30,20 +30,37 @@ Each dict uses the keys below (all optional — send what was read). Anything
else you include (e.g. a newly discovered parameter as `"p0xx_raw": 1234`) is else you include (e.g. a newly discovered parameter as `"p0xx_raw": 1234`) is
stored too and shows under "Other (unmapped)" on the inverter page. stored too and shows under "Other (unmapped)" on the inverter page.
| key | unit | source | State of the map as verified on site (2026-10-21):
|---|---|---|
| `ac_voltage_l1_v` / `_l2_v` / `_l3_v` | V | P050 / P05B / P064 raw / 40 | | key | unit | status | source |
| `dc_voltage_mppt1_v` / `_mppt2_v` | V | P052 / P054 raw / 40 | |---|---|---|---|
| `dc_current_mppt1_a` / `_mppt2_a` | A | P05A / P05C raw / 10 | | `ac_power_total_w` | W | ✅ sent | **Computed** by the poller: Σ (phase V × phase I), forced to 0 when the inverter isn't feeding. *Not* P06D — P06D sits latched at 21450 on any feeding unit (nameplate/limit, not live power). |
| `ac_current_l1_a` / `_l2_a` / `_l3_a` | A | P068 / P069 / P06A raw / 100 | | `ac_voltage_l1_v` / `_l2_v` / `_l3_v` | V | ✅ sent | P050 / P05B / P064 raw / 40 |
| `ac_power_total_w` | W | P06D raw | | `ac_current_l1_a` / `_l2_a` / `_l3_a` | A | ✅ sent | P068 / P069 / P06A raw / 100 |
| `grid_frequency_hz` | Hz | P06C raw / 20 | | `grid_frequency_hz` | Hz | ✅ sent | P06C raw / 20 |
| `temperature_c` | °C | P070 raw >> 16 | | `temperature_c` | °C | ✅ sent | P070 raw >> 16 |
| `daily_energy_wh` | Wh | P063 IND=0 raw × 10 | | `status_code` | – | ✅ sent | PZD status word. **7 and 8 = feeding** (7 on INV1's OEM board, 8 on the standard units); anything else shows as Standby. Other values not decoded yet. |
| `total_energy_wh` | Wh | P063 IND=11 raw | | `status_text` | – | ✅ sent | `"feeding"` / `"standby/not feeding"` |
| `status_code` | – | inverter state, once identified | | `dc_voltage_mppt1_v` / `_mppt2_v` | V | ❌ not sent | P052 / P054 are static nameplate/limit values, not live. Real registers TBD. |
| `error_code` | – | non-zero = fault (shows the inverter as **Fault**) | | `dc_current_mppt1_a` / `_mppt2_a` | A | ❌ not sent | P05A / P05C likewise static. Real registers TBD. |
| `status_text` | – | optional human text for the code | | `daily_energy_wh` | Wh | ❌ not sent | P063 IND=0 is frozen, not accumulating. Real register TBD. Until then the backend **estimates** daily energy by integrating `ac_power_total_w` (shown with ≈). |
| `total_energy_wh` | Wh | ❌ not sent | P063 IND=11 decode wrong. Real register TBD. Lifetime shows "not available yet". |
| `error_code` | – | ❌ not sent | No fault register confirmed yet. Absent = no fault. Non-zero will show the inverter as **Fault**. |
Unmapped diagnostics currently sent (stored, shown under "Other (unmapped)",
never treated as telemetry): `p06d_raw_latched`, `p052_static_v`,
`p05a_static_a`, `p063_ind0_raw`.
Inverter IDs (permanent database keys): INV1 = 192.168.1.11, INV2 =
192.168.1.12, INV3 = 192.168.1.13 (reserved, not connected yet), INV4 =
192.168.1.221, INV5 = REFUsol 20K-3T (reserved, no read path yet). An
inverter appears on the dashboard the first time it reports.
**Timestamps must be UTC.** Send them with the right offset (e.g.
`datetime.now(timezone.utc).isoformat()`), or leave `timestamp` out and let
`backend_client.py` add it. A reading stamped more than 5 min in the future
(e.g. local Athens time labelled `+00:00`) is stored at the time it was
received instead, and the response's `clamped_future` count says so.
`send()` stamps each reading with the current UTC time, buffers to `send()` stamps each reading with the current UTC time, buffers to
`unsent_readings.jsonl` when the internet is down and re-sends later, and `unsent_readings.jsonl` when the internet is down and re-sends later, and
+26 -35
View File
@@ -2,9 +2,11 @@
python fake_poller.py --url http://localhost:8090 --key change-me --backfill-days 30 python fake_poller.py --url http://localhost:8090 --key change-me --backfill-days 30
--backfill-days first loads that many days of history (one reading per Sends what the real poller sends today (AC side, temperature, status code,
5 minutes), then it posts live readings every --interval seconds. Inverter unmapped diagnostics; no DC or energy counters). --backfill-days first loads
INV3 runs with a dead MPPT2 string so the warnings show up. that many days of history (one reading per 5 minutes), then it posts live
readings every --interval seconds. INV4 runs at half output (as if a string
fuse had blown) so the warnings show up.
""" """
import argparse import argparse
@@ -15,7 +17,7 @@ from datetime import datetime, timedelta, timezone
from backend_client import BackendClient from backend_client import BackendClient
INVERTERS = ["INV1", "INV2", "INV3", "INV4", "INV5"] INVERTERS = ["INV1", "INV2", "INV4"]
PEAK_W = 18_000 PEAK_W = 18_000
@@ -26,40 +28,32 @@ def sun_factor(t: datetime) -> float:
return max(0.0, math.sin(math.pi * x)) if 0 < x < 1 else 0.0 return max(0.0, math.sin(math.pi * x)) if 0 < x < 1 else 0.0
def reading(inv: str, t: datetime, state: dict) -> dict | None: def reading(inv: str, t: datetime) -> dict | None:
f = sun_factor(t) * random.uniform(0.93, 1.0) f = sun_factor(t) * random.uniform(0.93, 1.0)
if f <= 0.01: if f <= 0.01:
return None # inverter asleep at night, doesn't answer return None # inverter asleep at night, doesn't answer
dead_mppt2 = inv == "INV3" feeding = f > 0.03
p_dc1 = PEAK_W / 2 * f w = int(PEAK_W * f * (0.5 if inv == "INV4" else 1.0)) if feeding else 0
p_dc2 = 0 if dead_mppt2 else PEAK_W / 2 * f volts = [round(random.uniform(229, 236), 2) for _ in range(3)]
v1, v2 = 560 + 60 * f, 560 + 60 * f amps = [round(w / 3 / v, 2) for v in volts]
ac = int((p_dc1 + p_dc2) * 0.97)
day = t.date()
if state.get((inv, "day")) != day:
state[(inv, "day")] = day
state[(inv, "daily")] = 0
state[(inv, "daily")] += ac * state["step"] / 3600
state[(inv, "total")] = state.get((inv, "total"), 40_000_000) + ac * state["step"] / 3600
i_ac = ac / 3 / 230
return { return {
"inverter_id": inv, "inverter_id": inv,
"timestamp": t.isoformat(timespec="seconds"), "timestamp": t.isoformat(timespec="seconds"),
"ac_voltage_l1_v": round(random.uniform(228, 236), 1), "ac_voltage_l1_v": volts[0],
"ac_voltage_l2_v": round(random.uniform(228, 236), 1), "ac_voltage_l2_v": volts[1],
"ac_voltage_l3_v": round(random.uniform(228, 236), 1), "ac_voltage_l3_v": volts[2],
"dc_voltage_mppt1_v": round(v1, 1), "ac_current_l1_a": amps[0],
"dc_voltage_mppt2_v": round(v2 if not dead_mppt2 else 30.0, 1), "ac_current_l2_a": amps[1],
"dc_current_mppt1_a": round(p_dc1 / v1, 1), "ac_current_l3_a": amps[2],
"dc_current_mppt2_a": round(p_dc2 / v2, 1), "ac_power_total_w": w,
"ac_current_l1_a": round(i_ac, 2),
"ac_current_l2_a": round(i_ac, 2),
"ac_current_l3_a": round(i_ac, 2),
"ac_power_total_w": ac,
"grid_frequency_hz": round(random.uniform(49.95, 50.05), 2), "grid_frequency_hz": round(random.uniform(49.95, 50.05), 2),
"temperature_c": int(30 + 25 * f), "temperature_c": int(30 + 25 * f),
"daily_energy_wh": int(state[(inv, "daily")] // 10 * 10), "status_code": (7 if inv == "INV1" else 8) if feeding else 3,
"total_energy_wh": int(state[(inv, "total")]), "status_text": "feeding" if feeding else "standby/not feeding",
"p06d_raw_latched": 21450,
"p052_static_v": 312.5,
"p05a_static_a": 45.0,
"p063_ind0_raw": 1872,
} }
@@ -72,13 +66,11 @@ def main() -> None:
args = ap.parse_args() args = ap.parse_args()
client = BackendClient(args.url, args.key, spool_path="fake_unsent.jsonl") client = BackendClient(args.url, args.key, spool_path="fake_unsent.jsonl")
state: dict = {}
if args.backfill_days: if args.backfill_days:
state["step"] = 300
t = datetime.now(timezone.utc) - timedelta(days=args.backfill_days) t = datetime.now(timezone.utc) - timedelta(days=args.backfill_days)
batch: list[dict] = [] batch: list[dict] = []
while t < datetime.now(timezone.utc): while t < datetime.now(timezone.utc):
batch += [r for inv in INVERTERS if (r := reading(inv, t, state))] batch += [r for inv in INVERTERS if (r := reading(inv, t))]
if len(batch) >= 1000: if len(batch) >= 1000:
client.send(batch) client.send(batch)
batch = [] batch = []
@@ -86,10 +78,9 @@ def main() -> None:
client.send(batch) client.send(batch)
print(f"Backfilled {args.backfill_days} days") print(f"Backfilled {args.backfill_days} days")
state["step"] = args.interval
while True: while True:
now = datetime.now(timezone.utc) now = datetime.now(timezone.utc)
batch = [r for inv in INVERTERS if (r := reading(inv, now, state))] batch = [r for inv in INVERTERS if (r := reading(inv, now))]
ok = client.send(batch) ok = client.send(batch)
print(f"{now:%H:%M:%S} sent {len(batch)} readings, ok={ok}") print(f"{now:%H:%M:%S} sent {len(batch)} readings, ok={ok}")
time.sleep(args.interval) time.sleep(args.interval)