docs: record the verified register map and inverter IDs
P06D is a latched 21450 (not power), P052/P05A static, P063 frozen; power is computed V*I. Lists what's sent, what isn't, the unmapped diagnostics, the INV1-INV5 IP assignments, and that timestamps must be real UTC. The simulator now sends the same payload shape. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -11,7 +11,8 @@ the on-site side: read the inverters, POST the values.
|
||||
use it to send. It's standard library only. It timestamps readings, keeps
|
||||
them in `unsent_readings.jsonl` when the internet is down, re-sends them
|
||||
later, and never raises.
|
||||
- `README.md` (next to this brief): the field names, units and scalings.
|
||||
- `README.md` (next to this brief): the field names, units and the current
|
||||
state of the register map (what's verified, what isn't sent yet).
|
||||
|
||||
## What to do every 60 s
|
||||
|
||||
@@ -44,9 +45,9 @@ while True:
|
||||
e.g. `INV1`..`INV5` matching labels on the units. It's the database key.
|
||||
Pretty names are set later in the dashboard, not here. Allowed characters:
|
||||
letters, digits, `_ . -`.
|
||||
3. **Send converted values**, not raw ones, using the keys and scalings in
|
||||
`README.md` (e.g. `ac_voltage_l1_v` = P050 raw / 40). Leave out anything
|
||||
you couldn't read; every field is optional.
|
||||
3. **Send converted values**, not raw ones, using the keys in `README.md`.
|
||||
Leave out anything you couldn't read or haven't verified; every field is
|
||||
optional. Timestamps must be real UTC (see README).
|
||||
4. **New or unconfirmed parameters:** send them too, under a descriptive key
|
||||
(e.g. `p0xx_raw`). The backend stores unknown keys and shows them on the
|
||||
inverter page under "Other (unmapped)". Tell the owner when a mapping is
|
||||
|
||||
Reference in New Issue
Block a user