docs: record the verified register map and inverter IDs

P06D is a latched 21450 (not power), P052/P05A static, P063 frozen; power
is computed V*I. Lists what's sent, what isn't, the unmapped diagnostics,
the INV1-INV5 IP assignments, and that timestamps must be real UTC. The
simulator now sends the same payload shape.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
2026-10-21 09:43:56 +03:00
co-authored by Claude Opus 5.5
parent d01cef991f
commit 42c7d18207
4 changed files with 80 additions and 55 deletions
+17 -1
View File
@@ -88,13 +88,29 @@ the chart picker without further changes.
datalogger is still posting and the sun is up. At night that's **Sleeping**;
if the datalogger itself is silent the state is **No data** (and a banner
says so).
- **Fault** — the reading carries a non-zero `error_code`.
- **Fault** — the reading carries a non-zero `error_code`. No `error_code`
(the poller doesn't send one yet) means no fault.
- **Feeding / Standby** — online and `status_code` is in
`FEEDING_STATUS_CODES` (7, 8) → Feeding; any other code → Standby. An
inverter in standby while its peers produce is caught by the
underperformance check below.
- **Check needed** — output below `UNDERPERFORM_RATIO` (75%) of the fleet
median over the last 10 min (per kWp once every inverter has its array size
set), or one MPPT input below half of the other.
Thresholds are in `.env`.
### Energy
Daily energy uses, in order: the inverter's daily counter
(`daily_energy_wh`), the growth of its lifetime counter, or — while neither
is decoded, which is the case today — AC power integrated over time
(trapezoid between consecutive readings, gaps over 5 min not bridged). The
estimate is flagged (`estimated: true` in the API, "≈" on the dashboard).
Lifetime energy shows "not available yet" until `total_energy_wh` is sent.
The current state of the register map is in `poller/README.md`.
## Data retention
Raw readings older than `RETENTION_DAYS` (730) are purged every 6 h. The