Device identity (serial/hw_family/hw_revision) has been read-only from production firmware since NVS provisioning — serial derives the MQTT password and hw_family/hw_revision select the OTA channel, so an uncontrolled write path could desync MQTT auth or brick OTA to the wrong hardware. This adds one narrow, deliberate exception: an MQTT-only system.set_identity command for correcting a mis-provisioned unit or reassigning a serial after a board swap, without a USB/serial reflash. Rejected over WebSocket/HTTP/UART by design (same pattern as identify's WebSocket-only check); requires all three fields together to avoid partial-identity states; forces a reboot after a successful write since MQTT credentials/hostname/AP SSID are derived from serial only once at boot. Firmware does not update the backend device record itself — that's the caller's (console's) responsibility in the same operation. Also includes docs/README.md's rule 6 (console API reference sync requirement) from an earlier uncommitted session, which this change follows. Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
26 KiB
Vesper Firmware — API Reference (v2)
Command reference for the Vesper Bell Automation System. Firmware v2 command bus architecture — all transports, all handlers. Last updated: 2026-03-16
Overview
Message Envelope
Every command sent to Vesper uses this JSON envelope:
{
"v": 2,
"cmd": "namespace.command",
"contents": { ... }
}
| Field | Type | Notes |
|---|---|---|
v |
int | Protocol version. 2 = current. Omit or set 1 for legacy (LegacyAdapter runs). |
cmd |
string | namespace.command format (e.g. relay.set_durations). |
contents |
object | Command payload. May be omitted if command takes no fields. |
Response Envelope
{
"status": "SUCCESS" | "ERROR",
"type": "command_name",
"payload": { ... }
}
payload is command-specific. On error, payload typically contains a "message" string.
Transports
| Transport | Address | Direction | Notes |
|---|---|---|---|
| MQTT | vesper/{device_id}/control |
Inbound commands | Responses go to vesper/{device_id}/data |
| MQTT | vesper/{device_id}/data |
Outbound responses + events | Command replies and bell overload notifications |
| MQTT | vesper/{device_id}/status/heartbeat |
Outbound, retained, QoS 1 | Heartbeat every 30s; server updates last_seen |
| MQTT | vesper/{device_id}/status/alerts |
Outbound, QoS 1 | Subsystem state-change events (published on change only) |
| MQTT | vesper/{device_id}/status/info |
Outbound, QoS 0 | General device state events (playback, reboot reason, etc.) |
| WebSocket | ws://{device_ip}/ws |
Bidirectional | Requires identify on connect |
| HTTP | http://{device_ip}/... |
REST | Web console endpoints |
| UART | Hardware serial | Bidirectional | Restricted — whitelist only (see below) |
| UDP | Port 32101 | Discovery broadcast | Passive — device announces itself |
UART Whitelist
Only the following commands are accepted over UART (LCD/button slave board). All others are silently dropped.
ping
playback
clock.pause
clock.resume
system.get_time
WebSocket — Client Identification
WebSocket clients must send identify immediately after connecting, or they will not receive targeted responses:
{ "v": 2, "cmd": "identify", "contents": { "device_type": "master" } }
device_type: "master" (app/console) or "secondary" (slave board).
Command Reference
ping
| Handler | SystemHandler |
| Transports | All |
| Contents | (none) |
| Returns | { "status": "SUCCESS", "type": "pong" } |
{ "v": 2, "cmd": "ping" }
identify
| Handler | SystemHandler |
| Transports | WebSocket only |
| Contents | device_type (required) |
{ "v": 2, "cmd": "identify", "contents": { "device_type": "master" } }
playback
| Handler | PlaybackHandler |
| Transports | All |
| Contents | action (required) + melody fields |
action values: "play", "stop", "pause", "unpause"
{ "v": 2, "cmd": "playback", "contents": { "action": "play", "pid": "ormilia_1_8", "speed": 200, "total_duration": 60000, "note_assignments": [1,2,3,4,5,6,0,0,0,0,0,0,0,0,0,0] } }
{ "v": 2, "cmd": "playback", "contents": { "action": "stop" } }
| Field | Type | Required | Notes |
|---|---|---|---|
action |
string | yes | "play" or "stop" |
pid |
string | yes (play) | Playback ID. Checked against built-in library first, then SD card, then downloaded via download_url. |
download_url |
string | no | URL to download the melody binary if not found locally. |
speed |
int | no | ms per beat. Default 500. |
total_duration |
int | no | Total playback ms. 0 = play to natural end. |
segment_duration |
int | no | Duration per loop segment (ms). Used with continuous_loop. |
pause_duration |
int | no | Pause between segments (ms). |
continuous_loop |
bool | no | Loop with pause/resume segments. |
note_assignments |
int[16] | no | Bell mapping (0-indexed note → 1-indexed output, 0 = unused). |
Relay Namespace — RelayHandler
relay.set_durations
Set strike duration (ms) for one or more bell channels. Partial updates accepted — omitted channels are unchanged.
| Required | At least one bell entry |
| Contents | { "bells": { "0": 95, "2": 110 } } |
{
"v": 2,
"cmd": "relay.set_durations",
"contents": { "bells": { "0": 95, "1": 100, "2": 110 } }
}
relay.set_outputs
Map bell channels to physical relay outputs. Partial updates accepted.
| Required | At least one bell entry |
| Contents | { "bells": { "0": 2, "1": 3 } } |
{
"v": 2,
"cmd": "relay.set_outputs",
"contents": { "bells": { "0": 2, "1": 3, "2": 4 } }
}
relay.get_config
Read current bell durations and output assignments.
| Required | (none) |
| Returns | { "durations": { "0": 95, ... }, "outputs": { "0": 2, ... } } |
{ "v": 2, "cmd": "relay.get_config" }
relay.test_output
Fire a specific relay for a caller-specified duration. Safety-gated: Player must be stopped.
| Required | output (int), duration_ms (int) |
| Notes | Both fields required — no defaults. Typical range: 85–140 ms. |
{
"v": 2,
"cmd": "relay.test_output",
"contents": { "output": 2, "duration_ms": 95 }
}
Clock Namespace — ClockHandler
clock.set_outputs
Set which relay outputs the clock strikes use.
| Required | At least one of c1, c2 |
| Contents | { "c1": 4, "c2": 5 } — partial OK |
clock.set_timings
Set clock strike timing configuration. Partial updates accepted.
clock.set_alerts
Configure hourly/quarter alert behavior. Partial updates accepted.
clock.set_backlight
Configure backlight behavior. Partial updates accepted.
clock.set_silence
Configure silence period (quiet hours). Partial updates accepted.
clock.set_time
Set the RTC time.
| Required | timestamp (Unix epoch, int) |
| Optional | timezone_offset (int, seconds), dst_offset (int, seconds) |
{
"v": 2,
"cmd": "clock.set_time",
"contents": { "timestamp": 1740000000, "timezone_offset": 7200 }
}
clock.set_face
Set the physical analog clock face position.
| Required | hour (int), minute (int) |
{ "v": 2, "cmd": "clock.set_face", "contents": { "hour": 10, "minute": 10 } }
clock.set_timezone
Set timezone independently of RTC time.
| Required | gmt_offset_sec (int) |
| Optional | dst_offset_sec (int), timezone_name (string) |
{
"v": 2,
"cmd": "clock.set_timezone",
"contents": { "gmt_offset_sec": 7200, "dst_offset_sec": 3600, "timezone_name": "Europe/Athens" }
}
clock.get_timezone
Read current timezone settings.
| Returns | { "gmt_offset_sec": 7200, "dst_offset_sec": 3600, "timezone_name": "..." } |
clock.sync_ntp
Force an immediate NTP time sync.
| Required | (none) |
clock.enable / clock.disable
Enable or disable clock strike output.
{ "v": 2, "cmd": "clock.enable" }
{ "v": 2, "cmd": "clock.disable" }
clock.pause / clock.resume
Pause or resume clock updates.
{ "v": 2, "cmd": "clock.pause" }
{ "v": 2, "cmd": "clock.resume" }
clock.get_face
Read current analog clock face position.
| Returns | { "clock_hour", "clock_minute", "last_sync_time", "next_output_is_c1" } |
clock.get_config
Read full clock configuration (outputs, timings, alerts, backlight, silence, enabled state).
System Namespace — SystemHandler
system.status
Get current device status: player state, strike counters, projected run time.
{ "v": 2, "cmd": "system.status" }
system.get_time
Get current RTC time.
| Returns | { "local_timestamp", "utc_timestamp", "year", "month", "day", "hour", "minute", "second", "rtc_available" } |
{ "v": 2, "cmd": "system.get_time" }
system.get_settings
Get full ConfigManager JSON dump (all saved settings).
{ "v": 2, "cmd": "system.get_settings" }
system.get_device_info
Get device identity and runtime stats.
| Returns | { "uid", "hw_type", "hw_version", "fw_version", "uptime_ms", "free_heap", "min_free_heap" } |
{ "v": 2, "cmd": "system.get_device_info" }
system.health
Get full HealthMonitor report — all subsystem states, warnings, critical failures.
{ "v": 2, "cmd": "system.health" }
system.factory_reset
Reset all settings to factory defaults.
Warning: Non-reversible. All saved configuration is wiped.
{ "v": 2, "cmd": "system.factory_reset" }
system.restart
Reboot the device. Response is sent before reboot (2s delay).
{ "v": 2, "cmd": "system.restart" }
system.set_identity
Overwrite the device's factory-set identity (serial, hw_family, hw_revision) in NVS and reboot to apply it. Intended for sysadmin use only — e.g. reassigning a serial after a board swap, or correcting a mis-provisioned unit — via the backend console, which is responsible for updating its own device record (including re-deriving the MQTT password from the new serial) in the same operation. Firmware does not touch the backend record itself.
Warning: Non-reversible from the device's perspective, and dangerous if the backend device record isn't updated to match — a serial mismatch will break MQTT auth (password is derived from serial), and a wrong
hw_family/hw_revisioncan pull an OTA build for the wrong hardware. Device restarts 2s after a successful response to apply the new identity.
| Handler | SystemHandler |
| Transports | MQTT only |
| Contents | serial (required), hw_family (required), hw_revision (required) |
{ "v": 2, "cmd": "system.set_identity", "contents": { "serial": "PV000000000001", "hw_family": "VS", "hw_revision": "01" } }
Errors:
| Message | Condition |
|---|---|
system.set_identity is only available via MQTT |
Sent over WebSocket, HTTP, or UART |
Missing required fields: serial, hw_family, hw_revision (all required) |
One or more fields absent or not a string |
serial, hw_family and hw_revision must be non-empty |
One or more fields present but empty |
Failed to persist new identity to NVS — device identity unchanged |
NVS write/commit failed |
Firmware Namespace — FirmwareHandler
firmware.status
Get firmware validation state.
| Returns | { "validation_state", "current_version", "is_testing", "is_valid", "boot_count", "build_date", "ota_channel", "startup_retry_count", "max_startup_retries", "runtime_failure_count", "max_runtime_failures", "backup_version", "backup_is_valid", "can_commit", "can_rollback", "runtime_timeout_ms"? } |
startup_retry_count, runtime_failure_count, and the backup partition fields are the OTA rollback safety-net's internal counters — previously only visible via serial/SD log output, now queryable remotely. Useful for diagnosing why a device rolled back an update. runtime_timeout_ms is only present while is_testing is true.
{ "v": 2, "cmd": "firmware.status" }
firmware.commit
Commit the current firmware as permanent (marks OTA slot as valid).
{ "v": 2, "cmd": "firmware.commit" }
firmware.rollback
Roll back to the previous firmware. Device reboots.
{ "v": 2, "cmd": "firmware.rollback" }
OTA Namespace — FirmwareHandler
ota.status
Get OTA update status.
| Returns | { "current_version", "available_version", "channel", "update_available", "last_check", "progress" } |
{ "v": 2, "cmd": "ota.status" }
ota.check
Check for available updates.
| Optional | channel (string, default "stable") |
{ "v": 2, "cmd": "ota.check", "contents": { "channel": "beta" } }
ota.update
Trigger OTA update from VPS. Device may reboot.
| Optional | channel (string, default "stable") |
{ "v": 2, "cmd": "ota.update", "contents": { "channel": "stable" } }
ota.custom
Flash firmware from a custom URL.
| Required | firmware_url (string) |
| Optional | checksum (string), file_size (int), version (string) |
{
"v": 2,
"cmd": "ota.custom",
"contents": {
"firmware_url": "http://example.com/firmware.bin",
"checksum": "abc123",
"version": "142"
}
}
Network Namespace — NetworkHandler
network.info
Get IP/gateway/DNS.
| Returns | { "ip", "gateway", "dns" } |
{ "v": 2, "cmd": "network.info" }
network.status
Get full connection state.
| Returns | { "connected", "state", "type", "ip", "rssi", "ap_mode" } |
{ "v": 2, "cmd": "network.status" }
network.set_config
Update network configuration. Partial updates accepted. Returns restart_required flag.
| Required | At least one field |
| Optional | hostname, useStaticIP, ip, gateway, subnet, dns1, dns2 |
| Notes | Static IP requires ip + gateway + subnet together |
{
"v": 2,
"cmd": "network.set_config",
"contents": { "hostname": "vesper-lab", "useStaticIP": false }
}
Files Namespace — FileHandler
files.list
List melody files on the SD card.
| Returns | Array of SD card melody file objects |
{ "v": 2, "cmd": "files.list" }
files.list_builtin
List all built-in melodies compiled into the firmware.
| Returns | [{ "name": "...", "pid": "..." }, ...] |
{ "v": 2, "cmd": "files.list_builtin" }
files.download
Download a melody from the server to the SD card.
| Required | melodys_uid (string) |
{ "v": 2, "cmd": "files.download", "contents": { "melodys_uid": "ABC123" } }
files.delete
Delete a melody from the SD card.
| Required | name (string) |
{ "v": 2, "cmd": "files.delete", "contents": { "name": "westminster.mel" } }
Log Namespace — LoggingHandler
Set log verbosity per output channel. Level 0 = off, 5 = verbose.
| Level | Meaning |
|---|---|
| 0 | None |
| 1 | Error |
| 2 | Warning |
| 3 | Info |
| 4 | Debug |
| 5 | Verbose |
log.set_serial
{ "v": 2, "cmd": "log.set_serial", "contents": { "level": 0 } }
log.set_sd
{ "v": 2, "cmd": "log.set_sd", "contents": { "level": 0 } }
log.set_mqtt
{ "v": 2, "cmd": "log.set_mqtt", "contents": { "level": 0 } }
logs.list
List day-rotated SD log files (/logs/YYYY-MM-DD.log). Requires an SD card — returns an error on boards without one.
| Returns | { "files": [{ "name": "2026-07-14.log", "size": 1234 }, ...] } |
{ "v": 2, "cmd": "logs.list" }
logs.download
Read a bounded chunk of a log file. Responses are capped at 4096 bytes regardless of file size — callers loop, feeding next_offset back in as offset, until eof is true. Requires an SD card.
| Required | file (string) — bare filename as returned by logs.list, no path separators |
| Optional | offset (int, default 0) |
| Returns | { "file", "data", "next_offset", "eof" } |
{ "v": 2, "cmd": "logs.download", "contents": { "file": "2026-07-14.log", "offset": 0 } }
Loop example: keep calling with contents.offset = <previous next_offset> until the response has "eof": true.
RF Remote Namespace — RFRemoteHandler
Available on hardware variants with
HAS_RF=1(e.g. Vesper, Vesper+). All commands are silently rejected on variants without RF hardware.
The RF subsystem uses a slot model: up to 16 independent slots, each binding one RF trigger code to a complete playback action. Slots are blank by default — nothing is pre-seeded. Program them over MQTT after flashing.
Slot object
| Field | Type | Required | Notes |
|---|---|---|---|
slot |
int | yes | Slot index, 0–15 |
rf_code |
uint32 | yes | Raw 433 MHz code that triggers this slot. Must be non-zero. |
pid |
string | yes (play) | Playback ID. Checked against built-in library first, then SD card. Use files.list_builtin or files.list for valid PIDs. |
speed |
int | no | ms per beat. Default 500. |
duration |
int | no | Total playback ms. Default 30000. 0 = play to natural end. |
note_assignments |
int[16] | no | Bell mapping array (0-indexed note → 1-indexed bell output, 0 = unused). Default all zeros. |
is_stop |
bool | no | If true, receiving this code calls force-stop (single press, no long-press required). pid/speed/duration ignored. Default false. |
note_assignments example: A melody written for 6 bells played on 3 physical bells, doubled:
"note_assignments": [1, 2, 3, 1, 2, 3, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0]
rf.set_slot
Program one slot, or multiple slots in a single command.
| Handler | RFRemoteHandler |
| Transports | All |
| Persists | NVS namespace rf (survives reboot) |
Single slot:
{
"v": 2,
"cmd": "rf.set_slot",
"contents": {
"slot": 0,
"rf_code": 9274392,
"pid": "vesper_fst_1_4",
"speed": 500,
"duration": 60000,
"note_assignments": [1, 2, 3, 4, 5, 6, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0],
"is_stop": false
}
}
Multiple slots (batch):
{
"v": 2,
"cmd": "rf.set_slot",
"contents": {
"slots": [
{ "slot": 0, "rf_code": 9274392, "pid": "vesper_fst_1_4", "speed": 500, "duration": 60000, "note_assignments": [1,2,3,4,5,6,0,0,0,0,0,0,0,0,0,0] },
{ "slot": 1, "rf_code": 9274388, "pid": "doxology_1_4", "speed": 500, "duration": 60000 },
{ "slot": 7, "rf_code": 9274385, "is_stop": true }
]
}
}
Returns:
{ "status": "SUCCESS", "type": "rf.set_slot", "payload": "3 slot(s) programmed" }
rf.clear_slot
Clear a single slot, or all slots.
| Required | slot — int (0–15) or string "all" |
{ "v": 2, "cmd": "rf.clear_slot", "contents": { "slot": 3 } }
{ "v": 2, "cmd": "rf.clear_slot", "contents": { "slot": "all" } }
rf.get_slots
Return the full slot table (all 16 slots).
| Contents | (none) |
| Returns | { "enabled": bool, "slots": [ { slot object } × 16 ] } |
Each entry includes an "empty": true/false field. Empty slots have rf_code: 0 and all other fields at their defaults.
{ "v": 2, "cmd": "rf.get_slots" }
Example response excerpt:
{
"status": "SUCCESS",
"type": "rf.get_slots",
"data": {
"enabled": true,
"slots": [
{
"slot": 0,
"empty": false,
"rf_code": 9274392,
"pid": "vesper_fst_1_4",
"speed": 500,
"duration": 60000,
"is_stop": false,
"note_assignments": [1, 2, 3, 4, 5, 6, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0]
},
{ "slot": 1, "empty": true, "rf_code": 0, ... },
...
]
}
}
rf.enable
Enable or disable RF reception at runtime.
| Required | enabled (bool) |
{ "v": 2, "cmd": "rf.enable", "contents": { "enabled": true } }
{ "v": 2, "cmd": "rf.enable", "contents": { "enabled": false } }
MQTT Namespace — MQTTHandler
mqtt.enable / mqtt.disable
Enable or disable MQTT connectivity.
{ "v": 2, "cmd": "mqtt.enable" }
{ "v": 2, "cmd": "mqtt.disable" }
Telemetry Namespace — TelemetryHandler
telemetry.get_strikes
Get strike counts per bell channel.
| Returns | { "strikes": { "0": 1234, "1": 567, ... } } |
{ "v": 2, "cmd": "telemetry.get_strikes" }
telemetry.reset_strikes
Reset strike counters. Omit bell to reset all channels; include it to reset one.
| Optional | bell (int) — channel index |
{ "v": 2, "cmd": "telemetry.reset_strikes" }
{ "v": 2, "cmd": "telemetry.reset_strikes", "contents": { "bell": 2 } }
telemetry.get_loads
Get heat load per bell channel, cooling status, and overload flags.
| Returns | { "loads": { "0": 42.5, ... }, "cooling_active": false, "overloaded": [2, 5] } |
{ "v": 2, "cmd": "telemetry.get_loads" }
MQTT Events (Unsolicited)
These messages are published by the device without a request. See mqtt-events.md for the full AsyncAPI-compatible reference.
| Topic | When | QoS | Retained | Format |
|---|---|---|---|---|
vesper/{id}/status/heartbeat |
Every 30s | 1 | yes | Heartbeat envelope |
vesper/{id}/status/alerts |
On subsystem state change only | 1 | no | Alert envelope |
vesper/{id}/status/info |
On device state change | 0 | no | Info envelope |
vesper/{id}/data |
Any command response / bell overload | 0 | no | Standard response envelope |
Heartbeat Payload
{
"status": "INFO",
"type": "heartbeat",
"payload": {
"device_id": "PV-26B18-VS01R-X7KQA",
"firmware_version": "142",
"timestamp": "Uptime: 5h 23m 45s",
"ip_address": "10.0.0.3",
"gateway": "10.0.0.1",
"uptime_ms": 19425000,
"rssi": -62
}
}
Subscribe to vesper/+/status/heartbeat to discover all online devices.
Alert Payload (vesper/{id}/status/alerts)
Published only when a subsystem state changes. The server should store the active alert set per device and update the display in place rather than appending a log entry.
{ "subsystem": "FileManager", "state": "WARNING", "msg": "ConfigManager health check failed" }
On recovery:
{ "subsystem": "FileManager", "state": "CLEARED" }
state values: WARNING | CRITICAL | FAILED | CLEARED
A fault-class boot reset also publishes here — subsystem: "System", e.g.:
{ "subsystem": "System", "state": "WARNING", "msg": "Device reset due to fault: TASK_WATCHDOG" }
Info Payload (vesper/{id}/status/info)
Published on significant device state changes. type identifies the event; payload is event-specific.
{ "type": "playback_started", "payload": { "pid": "ormilia_1_8" } }
{ "type": "playback_stopped", "payload": {} }
{ "type": "boot_reason", "payload": { "reason": "POWERON" } }
boot_reason is published once, the first time MQTT connects after boot — only for expected reset reasons (POWERON, SOFTWARE, DEEPSLEEP_WAKE, EXTERNAL_PIN, SDIO, UNKNOWN). Fault reasons (PANIC, TASK_WATCHDOG, INTERRUPT_WATCHDOG, OTHER_WATCHDOG, BROWNOUT) go to status/alerts instead (see above).
Legacy Compatibility (v1)
If a client sends "v": 1 (or omits v), the LegacyAdapter translates the old cmd + action pair to a v2 command before dispatch. No code changes needed on the client side during transition.
v1 cmd |
v1 action |
v2 cmd |
|---|---|---|
ping |
— | ping |
identify |
— | identify |
playback |
— | playback |
file_manager |
list_melodies |
files.list |
file_manager |
download_melody |
files.download |
file_manager |
delete_melody |
files.delete |
relay_setup |
set_timings |
relay.set_durations |
relay_setup |
set_outputs |
relay.set_outputs |
clock_setup |
set_outputs |
clock.set_outputs |
clock_setup |
set_timings |
clock.set_timings |
clock_setup |
set_alerts |
clock.set_alerts |
clock_setup |
set_backlight |
clock.set_backlight |
clock_setup |
set_silence |
clock.set_silence |
clock_setup |
set_rtc_time |
clock.set_time |
clock_setup |
set_physical_clock_time |
clock.set_face |
clock_setup |
pause_clock_updates |
clock.pause |
clock_setup |
resume_clock_updates |
clock.resume |
clock_setup |
set_enabled + enabled=true |
clock.enable |
clock_setup |
set_enabled + enabled=false |
clock.disable |
system_info |
report_status |
system.status |
system_info |
get_device_time |
system.get_time |
system_info |
get_clock_time |
clock.get_face |
system_info |
get_firmware_status |
firmware.status |
system_info |
network_info |
network.info |
system_info |
get_full_settings |
system.get_settings |
system_info |
sync_time_to_lcd |
system.get_time (LCD now uses request/response) |
system |
status |
system.status |
system |
reset_defaults |
system.factory_reset |
system |
commit_firmware |
firmware.commit |
system |
rollback_firmware |
firmware.rollback |
system |
get_firmware_status |
firmware.status |
system |
set_network_config |
network.set_config |
system |
set_serial_log_level |
log.set_serial |
system |
set_sd_log_level |
log.set_sd |
system |
set_mqtt_log_level |
log.set_mqtt |
system |
set_mqtt_enabled + enabled=true |
mqtt.enable |
system |
set_mqtt_enabled + enabled=false |
mqtt.disable |
system |
restart |
system.restart |
system |
reboot |
system.restart |
system |
force_update |
ota.update |
system |
custom_update |
ota.custom |
Quick Reference
| Namespace | Commands |
|---|---|
| (root) | ping, identify, playback |
relay |
set_durations, set_outputs, get_config, test_output |
clock |
set_outputs, set_timings, set_alerts, set_backlight, set_silence, set_time, set_face, set_timezone, get_timezone, sync_ntp, enable, disable, pause, resume, get_face, get_config |
system |
status, get_time, get_settings, get_device_info, health, factory_reset, restart |
firmware |
status, commit, rollback |
ota |
status, check, update, custom |
network |
info, status, set_config |
files |
list, list_builtin, download, delete |
log |
set_serial, set_sd, set_mqtt |
mqtt |
enable, disable |
telemetry |
get_strikes, reset_strikes, get_loads |
rf |
set_slot, clear_slot, get_slots, enable (HAS_RF variants only) |