The on-site agent found that the DC (P052/P054/P05A/P05C) and energy (P063) registers are static/frozen and ac_power_total_w is now computed V*I, so the backend and dashboard have to cope with those fields being absent. - Feeding/Standby from status_code (FEEDING_STATUS_CODES, default 7 and 8: INV1's OEM board uses 7). Online but not feeding = Standby; a standby inverter while peers produce is still caught by the underperformance check. Missing error_code stays "no fault". - Daily energy falls back to AC power integrated between readings, flagged estimated (≈ in the UI); out-of-order (spooled) readings recompute the day. Existing databases get the column and a rebuild on startup. - Totals are null instead of 0 when there's no energy data; lifetime shows "not available yet". Parameters the poller doesn't send are hidden on the detail page, DC lines only drawn when DC data exists. - Timestamps more than 5 min in the future are stored at receive time and counted in clamped_future — the example payload carried local Athens time labelled +00:00. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
52 lines
2.2 KiB
Bash
52 lines
2.2 KiB
Bash
# Host port the nginx container binds; point NPM (solar.bonamin.net) at it
|
|
HTTP_PORT=8090
|
|
|
|
# Shared secret: the on-site poller sends it as X-API-Key on POST /api/readings,
|
|
# and the dashboard asks for it when editing inverter settings.
|
|
# Generate one with: python -c "import secrets; print(secrets.token_urlsafe(32))"
|
|
API_KEY=change-me
|
|
|
|
# Site location — local day boundaries for daily energy, and the sun's
|
|
# elevation so inverters that switch off at night show "Sleeping", not "Offline".
|
|
# Leave LATITUDE/LONGITUDE empty to treat every silent inverter as offline.
|
|
SITE_TIMEZONE=Europe/Athens
|
|
SITE_LATITUDE=
|
|
SITE_LONGITUDE=
|
|
# Sun elevation (degrees) below which inverters are expected to be off
|
|
DAYLIGHT_MIN_ELEVATION=5
|
|
|
|
# Inverter counts as Online if its last reading is newer than this
|
|
ONLINE_WINDOW_SECONDS=300
|
|
# Raw readings older than this are purged (daily energy totals are kept)
|
|
RETENTION_DAYS=730
|
|
|
|
# Underperformance alarm: flag an inverter producing less than this fraction
|
|
# of the fleet median, averaged over the window. Skipped while the fleet makes
|
|
# less than the minimum (dawn/dusk/heavy cloud). The per-kWp minimum is used
|
|
# once every inverter has its array size (kWp) set, the W minimum otherwise.
|
|
UNDERPERFORM_RATIO=0.75
|
|
UNDERPERFORM_WINDOW_SECONDS=600
|
|
UNDERPERFORM_MIN_FLEET_W_PER_KWP=50
|
|
UNDERPERFORM_MIN_FLEET_W=1000
|
|
|
|
# String alarm: one MPPT input below this fraction of the other, once the
|
|
# stronger input exceeds MPPT_MIN_POWER_W (inverters set to 2 MPPTs only)
|
|
MPPT_IMBALANCE_RATIO=0.5
|
|
MPPT_MIN_POWER_W=1000
|
|
|
|
# status_code values meaning "feeding the grid" (JSON list): 8 on the
|
|
# standard units, 7 on INV1's OEM board. Any other code shows as Standby.
|
|
FEEDING_STATUS_CODES=[7, 8]
|
|
|
|
# Readings stamped more than this many seconds in the future (poller clock
|
|
# wrong, or local time sent as UTC) are stored at the time they arrive.
|
|
MAX_FUTURE_SKEW_SECONDS=300
|
|
|
|
# Daily energy is estimated by integrating AC power while the energy counters
|
|
# aren't decoded; gaps between readings longer than this aren't bridged.
|
|
ENERGY_INTEGRATION_MAX_GAP_SECONDS=300
|
|
|
|
# Browser origins allowed to call the API directly (JSON list). The dashboard
|
|
# itself is same-origin and doesn't need this.
|
|
CORS_ORIGINS=["*"]
|