Files
refusol-datalogging/poller/fake_poller.py
T
bonaminandClaude Opus 5.5 42c7d18207 docs: record the verified register map and inverter IDs
P06D is a latched 21450 (not power), P052/P05A static, P063 frozen; power
is computed V*I. Lists what's sent, what isn't, the unmapped diagnostics,
the INV1-INV5 IP assignments, and that timestamps must be real UTC. The
simulator now sends the same payload shape.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-21 09:43:56 +03:00

91 lines
3.2 KiB
Python
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
"""Simulated inverters for trying the dashboard without the real site.
python fake_poller.py --url http://localhost:8090 --key change-me --backfill-days 30
Sends what the real poller sends today (AC side, temperature, status code,
unmapped diagnostics; no DC or energy counters). --backfill-days first loads
that many days of history (one reading per 5 minutes), then it posts live
readings every --interval seconds. INV4 runs at half output (as if a string
fuse had blown) so the warnings show up.
"""
import argparse
import math
import random
import time
from datetime import datetime, timedelta, timezone
from backend_client import BackendClient
INVERTERS = ["INV1", "INV2", "INV4"]
PEAK_W = 18_000
def sun_factor(t: datetime) -> float:
# Rough local solar day 06:30–19:30 UTC+3, sine shaped
hour = (t.hour + 3 + t.minute / 60) % 24
x = (hour - 6.5) / 13
return max(0.0, math.sin(math.pi * x)) if 0 < x < 1 else 0.0
def reading(inv: str, t: datetime) -> dict | None:
f = sun_factor(t) * random.uniform(0.93, 1.0)
if f <= 0.01:
return None # inverter asleep at night, doesn't answer
feeding = f > 0.03
w = int(PEAK_W * f * (0.5 if inv == "INV4" else 1.0)) if feeding else 0
volts = [round(random.uniform(229, 236), 2) for _ in range(3)]
amps = [round(w / 3 / v, 2) for v in volts]
return {
"inverter_id": inv,
"timestamp": t.isoformat(timespec="seconds"),
"ac_voltage_l1_v": volts[0],
"ac_voltage_l2_v": volts[1],
"ac_voltage_l3_v": volts[2],
"ac_current_l1_a": amps[0],
"ac_current_l2_a": amps[1],
"ac_current_l3_a": amps[2],
"ac_power_total_w": w,
"grid_frequency_hz": round(random.uniform(49.95, 50.05), 2),
"temperature_c": int(30 + 25 * f),
"status_code": (7 if inv == "INV1" else 8) if feeding else 3,
"status_text": "feeding" if feeding else "standby/not feeding",
"p06d_raw_latched": 21450,
"p052_static_v": 312.5,
"p05a_static_a": 45.0,
"p063_ind0_raw": 1872,
}
def main() -> None:
ap = argparse.ArgumentParser()
ap.add_argument("--url", default="http://localhost:8090")
ap.add_argument("--key", default="change-me")
ap.add_argument("--backfill-days", type=int, default=0)
ap.add_argument("--interval", type=int, default=60)
args = ap.parse_args()
client = BackendClient(args.url, args.key, spool_path="fake_unsent.jsonl")
if args.backfill_days:
t = datetime.now(timezone.utc) - timedelta(days=args.backfill_days)
batch: list[dict] = []
while t < datetime.now(timezone.utc):
batch += [r for inv in INVERTERS if (r := reading(inv, t))]
if len(batch) >= 1000:
client.send(batch)
batch = []
t += timedelta(minutes=5)
client.send(batch)
print(f"Backfilled {args.backfill_days} days")
while True:
now = datetime.now(timezone.utc)
batch = [r for inv in INVERTERS if (r := reading(inv, now))]
ok = client.send(batch)
print(f"{now:%H:%M:%S} sent {len(batch)} readings, ok={ok}")
time.sleep(args.interval)
if __name__ == "__main__":
main()