bonaminandClaude Opus 5.5 8029468fb1 feat(api): shared view settings, recent readings, last production run
Groundwork for the dashboard settings page and the five-inverter contract:

- GET/PUT /api/settings stores display options (comparison averaging,
  scale and reference, power chart range and smoothing, voltage display,
  default language) in the meta table. Shared by every viewer since there
  are no accounts; PUT needs the API key so a public visitor can't change
  everyone's view. Unknown keys are ignored, missing ones take defaults.
- /api/summary returns each inverter's last few readings (recent_power) so
  the comparison can average out one reading taken under a passing cloud.
- Offline is now judged per inverter: a couple of missed cycles at the
  unit's own cadence (INV5 is cloud-polled every ~5 min), never below
  ONLINE_WINDOW_SECONDS. Before, INV5 flapped offline between reports.
- /api/power?last_run=true covers the latest production run, split at
  night silences; units reporting 0 W overnight don't join runs.
- Issues carry params so clients can render them in Greek.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-22 17:59:33 +03:00
..