Files
bonaminandClaude Opus 5.5 42c7d18207 docs: record the verified register map and inverter IDs
P06D is a latched 21450 (not power), P052/P05A static, P063 frozen; power
is computed V*I. Lists what's sent, what isn't, the unmapped diagnostics,
the INV1-INV5 IP assignments, and that timestamps must be real UTC. The
simulator now sends the same payload shape.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-21 09:43:56 +03:00

3.9 KiB
Raw Permalink Blame History

On-site poller

refusol_poller.py (lives on the site laptop, not in this repo) reads the inverters over USS/TCP (port 21062, USS address 0). It sends each cycle to the backend through backend_client.py — copy that file next to the poller.

Wiring it into refusol_poller.py

At the top of the file:

from backend_client import BackendClient

BACKEND_URL = "https://solar.bonamin.net"
API_KEY = "same value as API_KEY in the server's .env"

backend = BackendClient(BACKEND_URL, API_KEY)

At the end of every poll cycle, one dict per inverter that answered:

readings = []
for inverter_id, values in polled.items():      # however the poller holds them
    readings.append({"inverter_id": inverter_id, **values})
backend.send(readings)                          # also call it when the list is empty

Each dict uses the keys below (all optional — send what was read). Anything else you include (e.g. a newly discovered parameter as "p0xx_raw": 1234) is stored too and shows under "Other (unmapped)" on the inverter page.

State of the map as verified on site (2026-10-21):

key unit status source
ac_power_total_w W ✅ sent Computed by the poller: Σ (phase V × phase I), forced to 0 when the inverter isn't feeding. Not P06D — P06D sits latched at 21450 on any feeding unit (nameplate/limit, not live power).
ac_voltage_l1_v / _l2_v / _l3_v V ✅ sent P050 / P05B / P064 raw / 40
ac_current_l1_a / _l2_a / _l3_a A ✅ sent P068 / P069 / P06A raw / 100
grid_frequency_hz Hz ✅ sent P06C raw / 20
temperature_c °C ✅ sent P070 raw >> 16
status_code – ✅ sent PZD status word. 7 and 8 = feeding (7 on INV1's OEM board, 8 on the standard units); anything else shows as Standby. Other values not decoded yet.
status_text – ✅ sent "feeding" / "standby/not feeding"
dc_voltage_mppt1_v / _mppt2_v V ❌ not sent P052 / P054 are static nameplate/limit values, not live. Real registers TBD.
dc_current_mppt1_a / _mppt2_a A ❌ not sent P05A / P05C likewise static. Real registers TBD.
daily_energy_wh Wh ❌ not sent P063 IND=0 is frozen, not accumulating. Real register TBD. Until then the backend estimates daily energy by integrating ac_power_total_w (shown with ≈).
total_energy_wh Wh ❌ not sent P063 IND=11 decode wrong. Real register TBD. Lifetime shows "not available yet".
error_code – ❌ not sent No fault register confirmed yet. Absent = no fault. Non-zero will show the inverter as Fault.

Unmapped diagnostics currently sent (stored, shown under "Other (unmapped)", never treated as telemetry): p06d_raw_latched, p052_static_v, p05a_static_a, p063_ind0_raw.

Inverter IDs (permanent database keys): INV1 = 192.168.1.11, INV2 = 192.168.1.12, INV3 = 192.168.1.13 (reserved, not connected yet), INV4 = 192.168.1.221, INV5 = REFUsol 20K-3T (reserved, no read path yet). An inverter appears on the dashboard the first time it reports.

Timestamps must be UTC. Send them with the right offset (e.g. datetime.now(timezone.utc).isoformat()), or leave timestamp out and let backend_client.py add it. A reading stamped more than 5 min in the future (e.g. local Athens time labelled +00:00) is stored at the time it was received instead, and the response's clamped_future count says so.

send() stamps each reading with the current UTC time, buffers to unsent_readings.jsonl when the internet is down and re-sends later, and never raises — a backend problem can't stop the polling loop.

Call send([]) even when no inverter answered. That's the heartbeat that lets the dashboard say "inverter not responding" (site online) instead of "datalogger offline" (site/internet down).

Trying the dashboard without the site

python fake_poller.py --url http://localhost:8090 --key change-me --backfill-days 30