Files
bonaminandClaude Opus 5.5 8029468fb1 feat(api): shared view settings, recent readings, last production run
Groundwork for the dashboard settings page and the five-inverter contract:

- GET/PUT /api/settings stores display options (comparison averaging,
  scale and reference, power chart range and smoothing, voltage display,
  default language) in the meta table. Shared by every viewer since there
  are no accounts; PUT needs the API key so a public visitor can't change
  everyone's view. Unknown keys are ignored, missing ones take defaults.
- /api/summary returns each inverter's last few readings (recent_power) so
  the comparison can average out one reading taken under a passing cloud.
- Offline is now judged per inverter: a couple of missed cycles at the
  unit's own cadence (INV5 is cloud-polled every ~5 min), never below
  ONLINE_WINDOW_SECONDS. Before, INV5 flapped offline between reports.
- /api/power?last_run=true covers the latest production run, split at
  night silences; units reporting 0 W overnight don't join runs.
- Issues carry params so clients can render them in Greek.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-22 17:59:33 +03:00

193 lines
6.2 KiB
Python

from datetime import datetime
from typing import Any, Literal
from pydantic import BaseModel, ConfigDict, Field
InverterId = Field(min_length=1, max_length=64, pattern=r"^[A-Za-z0-9_.\-]+$")
class ReadingIn(BaseModel):
"""One inverter's values from one poll cycle.
Every parameter is optional — send what the poller could read. Unknown
keys are accepted and stored in `extra` (as are keys of an explicit
`extra` object), so new parameters can be logged before the backend
knows about them.
"""
model_config = ConfigDict(extra="allow")
inverter_id: str = InverterId
timestamp: datetime | None = Field(
default=None, description="UTC. Defaults to the time the backend receives it."
)
ac_voltage_l1_v: float | None = None
ac_voltage_l2_v: float | None = None
ac_voltage_l3_v: float | None = None
dc_voltage_mppt1_v: float | None = None
dc_voltage_mppt2_v: float | None = None
dc_current_mppt1_a: float | None = None
dc_current_mppt2_a: float | None = None
ac_current_l1_a: float | None = None
ac_current_l2_a: float | None = None
ac_current_l3_a: float | None = None
ac_power_total_w: int | None = None
grid_frequency_hz: float | None = None
temperature_c: int | None = None
daily_energy_wh: int | None = None
total_energy_wh: int | None = None
status_code: int | None = Field(default=None, description="Raw inverter state, if known")
error_code: int | None = Field(default=None, description="Non-zero = inverter reports a fault")
status_text: str | None = Field(default=None, max_length=200)
extra: dict[str, Any] | None = None
class IngestResult(BaseModel):
received: int
stored: int
duplicates: int
clamped_future: int = Field(
description="Readings stamped in the future (clock wrong, or local time sent as UTC); "
"stored at the time they were received instead"
)
class InverterUpdate(BaseModel):
name: str | None = Field(default=None, max_length=100)
capacity_kwp: float | None = Field(default=None, ge=0, le=1000)
mppt_count: int | None = Field(default=None, ge=1, le=4)
sort_order: int | None = None
notes: str | None = Field(default=None, max_length=2000)
class Inverter(BaseModel):
id: str
name: str
capacity_kwp: float | None
mppt_count: int
sort_order: int
notes: str | None
first_seen: datetime | None
last_seen: datetime | None
Severity = Literal["info", "warning", "critical"]
State = Literal["ok", "standby", "warning", "fault", "offline", "sleeping", "unknown"]
class Issue(BaseModel):
code: str
severity: Severity
message: str
params: dict[str, Any] = Field(
default_factory=dict,
description="Values inside the message, so clients can render it in their own language",
)
class Health(BaseModel):
online: bool = Field(description="A reading arrived within ONLINE_WINDOW_SECONDS")
feeding: bool | None = Field(
description="status_code is one of FEEDING_STATUS_CODES; null when no status_code is reported"
)
state: State
issues: list[Issue]
avg_power_w: float | None = Field(description="Mean AC power over the comparison window")
relative_output: float | None = Field(
description="Output vs fleet median (1.0 = median), per kWp when capacities are set"
)
online_window_seconds: int = Field(
description="Silence after which this inverter counts as offline: ONLINE_WINDOW_SECONDS, "
"stretched for units that report slowly (e.g. cloud-polled every 5 min)"
)
class EnergyToday(BaseModel):
wh: int | None
estimated: bool = Field(description="Integrated from AC power, not the inverter's own counter")
class RecentPower(BaseModel):
timestamp: datetime
ac_power_total_w: int | None
class InverterStatus(BaseModel):
inverter: Inverter
health: Health
energy_today: EnergyToday
latest: dict[str, Any] | None
recent_power: list[RecentPower] = Field(
description="Up to the last 5 readings of the past 30 min, newest first — lets clients "
"average out a single reading taken while a cloud shaded one array"
)
class Totals(BaseModel):
ac_power_w: int
daily_energy_wh: int | None
daily_energy_estimated: bool
total_energy_wh: int | None = Field(description="Null until the inverters report a lifetime counter")
inverter_count: int
online_count: int
feeding_count: int
problem_count: int
class Datalogger(BaseModel):
online: bool
last_ingest_at: datetime | None
class Sun(BaseModel):
elevation: float | None
daylight: bool | None
PowerRange = Literal["30m", "1h", "3h", "6h", "24h", "run", "3d", "7d", "30d"]
class ViewSettings(BaseModel):
"""Dashboard display options. Shared by every viewer (there are no user
accounts); unknown keys are ignored and missing ones take the default,
so older and newer clients can coexist."""
model_config = ConfigDict(extra="ignore")
# Output comparison
comparison_readings: Literal[1, 3, 5] = Field(
default=1, description="Average the last N readings per inverter (1 = latest only)"
)
comparison_scale: Literal["auto", "max", "custom"] = Field(
default="auto",
description="Bar length: auto = rounded-up ceiling above the highest, "
"max = highest inverter is a full bar, custom = comparison_custom_kw is a full bar",
)
comparison_custom_kw: float | None = Field(default=None, gt=0, le=1000)
comparison_reference: Literal["median", "best", "custom"] = Field(
default="median", description="What the percentage is relative to"
)
# Fleet power chart
power_range: PowerRange = "24h"
power_smoothing: Literal["off", "light", "strong"] = "off"
# Display
voltage_display: Literal["phase", "line"] = Field(
default="phase",
description="phase = line-to-neutral as sent (~240 V); line = x√3, matches the inverter screen (~415 V)",
)
default_language: Literal["en", "el"] = "el"
class Summary(BaseModel):
generated_at: datetime
datalogger: Datalogger
sun: Sun
totals: Totals
fleet_median_w_per_kwp: float | None
inverters: list[InverterStatus]