"""Simulated inverters for trying the dashboard without the real site. python fake_poller.py --url http://localhost:8090 --key change-me --backfill-days 30 Follows the poller data contract of 2026-10-22: five units, three sources. INV1/INV3 (OEM board) send AC voltages, power, frequency, temperature and status; INV2/INV4 (SunSpec) add phase currents and MPPT1 voltage; INV5 (SolarmanPV cloud) adds the real daily/lifetime energy counters, reports only every 5 min and keeps reporting 0 W / Standby at night while the others go silent. --backfill-days first loads that many days of history (one reading per 5 minutes), then it posts live readings every --interval seconds. INV4 runs at half output (as if a string fuse had blown) so the warnings show up. """ import argparse import math import random import time from datetime import datetime, timedelta, timezone from backend_client import BackendClient INVERTERS = ["INV1", "INV2", "INV3", "INV4", "INV5"] PEAK_W = 18_000 CLOUD_EVERY_S = 300 # INV5's cadence INV5_LIFETIME_START_WH = 41_250_000 # INV5's daily counter, accumulated by the simulator _inv5 = {"day": None, "daily_wh": 0.0, "total_wh": float(INV5_LIFETIME_START_WH), "last": None} def sun_factor(t: datetime) -> float: # Rough local solar day 06:30–19:30 UTC+3, sine shaped hour = (t.hour + 3 + t.minute / 60) % 24 x = (hour - 6.5) / 13 return max(0.0, math.sin(math.pi * x)) if 0 < x < 1 else 0.0 def reading(inv: str, t: datetime) -> dict | None: f = sun_factor(t) * random.uniform(0.93, 1.0) if inv == "INV5": if int(t.timestamp()) % CLOUD_EVERY_S >= 60: return None # cloud value only refreshes every 5 min elif f <= 0.01: return None # local units power down at night and don't answer feeding = f > 0.03 w = int(PEAK_W * f * (0.5 if inv == "INV4" else 1.0)) if feeding else 0 volts = [round(random.uniform(236, 244), 1) for _ in range(3)] r = { "inverter_id": inv, "timestamp": t.isoformat(timespec="seconds"), "ac_voltage_l1_v": volts[0], "ac_voltage_l2_v": volts[1], "ac_voltage_l3_v": volts[2], "ac_power_total_w": w, "grid_frequency_hz": round(random.uniform(49.95, 50.05), 2), "temperature_c": int(30 + 25 * f), "status_code": 8 if feeding else 1, "status_text": ("MPP" if feeding else "Standby") if inv != "INV5" else ("Generating" if feeding else "Standby"), } if inv in ("INV1", "INV3"): r["raw_status_oem"] = 7 if feeding else 3 return r r.update({f"ac_current_l{i + 1}_a": round(w / 3 / v, 2) for i, v in enumerate(volts)}) r["dc_voltage_mppt1_v"] = round(random.uniform(560, 640), 1) if feeding else 0.0 if inv in ("INV2", "INV4"): r["raw_status_sunspec"] = 4 if feeding else 2 return r day = (t + timedelta(hours=3)).date() if _inv5["day"] != day: _inv5.update(day=day, daily_wh=0.0) if _inv5["last"] is not None: wh = w * (t - _inv5["last"]).total_seconds() / 3600 _inv5["daily_wh"] += wh _inv5["total_wh"] += wh _inv5["last"] = t r.update(daily_energy_wh=int(_inv5["daily_wh"]), total_energy_wh=int(_inv5["total_wh"]), raw_status_cloud=1 if feeding else 0) return r def main() -> None: ap = argparse.ArgumentParser() ap.add_argument("--url", default="http://localhost:8090") ap.add_argument("--key", default="change-me") ap.add_argument("--backfill-days", type=int, default=0) ap.add_argument("--interval", type=int, default=60) args = ap.parse_args() client = BackendClient(args.url, args.key, spool_path="fake_unsent.jsonl") if args.backfill_days: now = int(time.time()) # On the 5-min grid, so INV5's cloud readings land in the backfill too t = datetime.fromtimestamp(now - now % CLOUD_EVERY_S - args.backfill_days * 86400, timezone.utc) batch: list[dict] = [] while t < datetime.now(timezone.utc): batch += [r for inv in INVERTERS if (r := reading(inv, t))] if len(batch) >= 1000: client.send(batch) batch = [] t += timedelta(minutes=5) client.send(batch) print(f"Backfilled {args.backfill_days} days") while True: now = datetime.now(timezone.utc) batch = [r for inv in INVERTERS if (r := reading(inv, now))] ok = client.send(batch) print(f"{now:%H:%M:%S} sent {len(batch)} readings, ok={ok}") time.sleep(args.interval) if __name__ == "__main__": main()