# Brief: sending inverter readings to the Solar Monitor backend You are building (or updating) the script on the site laptop that reads the Refusol 020K inverters over USS/TCP and reports to the backend. The backend and dashboard already run at **https://solar.bonamin.net**. Your job is only the on-site side: read the inverters, POST the values. ## Files to use - `backend_client.py` (next to this brief): copy it next to your script and use it to send. It's standard library only. It timestamps readings, keeps them in `unsent_readings.jsonl` when the internet is down, re-sends them later, and never raises. - `README.md` (next to this brief): the field names, units and the current state of the register map (what's verified, what isn't sent yet). ## What to do every 60 s ```python from backend_client import BackendClient BACKEND_URL = "https://solar.bonamin.net" API_KEY = "" backend = BackendClient(BACKEND_URL, API_KEY) while True: readings = [] for inv in INVERTERS: # e.g. [{"id": "INV1", "host": "192.168.1.51"}, ...] try: values = read_inverter(inv) # your USS code -> dict of converted values readings.append({"inverter_id": inv["id"], **values}) except Exception as e: log.warning("%s not answering: %s", inv["id"], e) # just leave it out: the dashboard marks it Offline (by day) or Sleeping (at night) backend.send(readings) # ALWAYS call it, even with an empty list sleep_until_next_minute() ``` ## Rules that matter 1. **Always call `send()`, even with an empty list.** The empty list is the heartbeat. It's how the dashboard tells "inverter dead" (laptop still reporting) apart from "site/internet down". 2. **`inverter_id` must stay the same forever** for each physical inverter, e.g. `INV1`..`INV5` matching labels on the units. It's the database key. Pretty names are set later in the dashboard, not here. Allowed characters: letters, digits, `_ . -`. 3. **Send converted values**, not raw ones, using the keys in `README.md`. Leave out anything you couldn't read or haven't verified; every field is optional. Timestamps must be real UTC (see README). 4. **New or unconfirmed parameters:** send them too, under a descriptive key (e.g. `p0xx_raw`). The backend stores unknown keys and shows them on the inverter page under "Other (unmapped)". Tell the owner when a mapping is confirmed so it gets promoted to a proper field. 5. **Fault status:** if you find the parameter holding the inverter's state/error code, send it as `status_code` / `error_code` (non-zero `error_code` = the dashboard shows **Fault**), with an optional `status_text`. This is high priority: it's the most direct "is it broken?" signal. 6. A failed inverter read must never stop the loop or the other inverters. 7. Run it so it survives reboots: Windows Task Scheduler "at startup" or a service; systemd on Linux. ## Checking it works ```bash curl -X POST https://solar.bonamin.net/api/readings \ -H "X-API-Key: " -H "Content-Type: application/json" \ -d '[{"inverter_id":"INV1","ac_power_total_w":1234}]' # use a real inverter id: every id sent shows up as an inverter on the dashboard # -> {"received":1,"stored":1,"duplicates":0} ``` Then open https://solar.bonamin.net. The inverter appears within 30 s. API reference: https://solar.bonamin.net/api/docs