# On-site poller `refusol_poller.py` (not in this repo yet) reads the inverters over USS/TCP (port 21062, USS address 0). It sends each cycle to the backend through `backend_client.py` — copy that file next to the poller. ## Wiring it into `refusol_poller.py` At the top of the file: ```python from backend_client import BackendClient BACKEND_URL = "https://solar.bonamin.net" API_KEY = "same value as API_KEY in the server's .env" backend = BackendClient(BACKEND_URL, API_KEY) ``` At the end of every poll cycle, one dict per inverter that answered: ```python readings = [] for inverter_id, values in polled.items(): # however the poller holds them readings.append({"inverter_id": inverter_id, **values}) backend.send(readings) # also call it when the list is empty ``` Each dict uses the keys below (all optional — send what was read). Anything else you include (e.g. a newly discovered parameter as `"p0xx_raw": 1234`) is stored too and shows under "Other (unmapped)" on the inverter page. | key | unit | source | |---|---|---| | `ac_voltage_l1_v` / `_l2_v` / `_l3_v` | V | P050 / P05B / P064 raw / 40 | | `dc_voltage_mppt1_v` / `_mppt2_v` | V | P052 / P054 raw / 40 | | `dc_current_mppt1_a` / `_mppt2_a` | A | P05A / P05C raw / 10 | | `ac_current_l1_a` / `_l2_a` / `_l3_a` | A | P068 / P069 / P06A raw / 100 | | `ac_power_total_w` | W | P06D raw | | `grid_frequency_hz` | Hz | P06C raw / 20 | | `temperature_c` | °C | P070 raw >> 16 | | `daily_energy_wh` | Wh | P063 IND=0 raw × 10 | | `total_energy_wh` | Wh | P063 IND=11 raw | | `status_code` | – | inverter state, once identified | | `error_code` | – | non-zero = fault (shows the inverter as **Fault**) | | `status_text` | – | optional human text for the code | `send()` stamps each reading with the current UTC time, buffers to `unsent_readings.jsonl` when the internet is down and re-sends later, and never raises — a backend problem can't stop the polling loop. **Call `send([])` even when no inverter answered.** That's the heartbeat that lets the dashboard say "inverter not responding" (site online) instead of "datalogger offline" (site/internet down). ## Trying the dashboard without the site ```bash python fake_poller.py --url http://localhost:8090 --key change-me --backfill-days 30 ```