Commit Graph
3 Commits
Author SHA1 Message Date
bonaminandClaude Opus 5.5 42c7d18207 docs: record the verified register map and inverter IDs
P06D is a latched 21450 (not power), P052/P05A static, P063 frozen; power
is computed V*I. Lists what's sent, what isn't, the unmapped diagnostics,
the INV1-INV5 IP assignments, and that timestamps must be real UTC. The
simulator now sends the same payload shape.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-21 09:43:56 +03:00
bonaminandClaude Opus 5.5 0b0e4b7d6d docs(poller): test the endpoint with a real inverter id, not TEST
Any id posted becomes a permanent inverter card, and there's no delete yet.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-21 09:02:22 +03:00
bonaminandClaude Opus 5.5 9d41c77668 docs(poller): brief for the agent building the on-site poller
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-21 09:02:12 +03:00