bonaminandClaude Opus 5.5 d01cef991f feat: match the verified on-site poller payload
The on-site agent found that the DC (P052/P054/P05A/P05C) and energy (P063)
registers are static/frozen and ac_power_total_w is now computed V*I, so
the backend and dashboard have to cope with those fields being absent.

- Feeding/Standby from status_code (FEEDING_STATUS_CODES, default 7 and 8:
  INV1's OEM board uses 7). Online but not feeding = Standby; a standby
  inverter while peers produce is still caught by the underperformance
  check. Missing error_code stays "no fault".
- Daily energy falls back to AC power integrated between readings, flagged
  estimated (≈ in the UI); out-of-order (spooled) readings recompute the
  day. Existing databases get the column and a rebuild on startup.
- Totals are null instead of 0 when there's no energy data; lifetime shows
  "not available yet". Parameters the poller doesn't send are hidden on the
  detail page, DC lines only drawn when DC data exists.
- Timestamps more than 5 min in the future are stored at receive time and
  counted in clamped_future — the example payload carried local Athens time
  labelled +00:00.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-21 09:43:55 +03:00
bonaminandClaude Opus 5.5 d4b584e364 feat: solar inverter monitor — FastAPI + SQLite backend, React PWA dashboard
Monitoring for the Refusol 020K inverters. The on-site poller POSTs each
60 s cycle to /api/readings; the dashboard answers first whether every
inverter is operating and whether one is producing far less than its peers
(string fuse / breaker problems).

- Backend: FastAPI + SQLite. Parameters defined once in fields.py (columns
  auto-added on start); unknown poller keys are kept in `extra` since the
  parameter map is still being researched. Idempotent ingest, daily energy
  rollup in site-local days, history downsampling, 2-year retention.
- Health: Offline vs Sleeping (sun elevation) vs No data (datalogger
  silent, detected via empty-batch heartbeats), Fault from error_code,
  underperformance vs fleet median (per kWp when sizes set), MPPT imbalance.
- Frontend: mobile-first React + Tailwind, installable PWA, comparison bars,
  24 h power / 30 day energy charts, detail page with all parameters.
- Docker: backend + frontend + nginx on one port for NPM, as in
  bellsystems-cp; deploy-host.sh pulls main and rebuilds.
- poller/backend_client.py: stdlib client with offline spool for
  refusol_poller.py; fake_poller.py simulates the site.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>