feat: match the verified on-site poller payload

The on-site agent found that the DC (P052/P054/P05A/P05C) and energy (P063)
registers are static/frozen and ac_power_total_w is now computed V*I, so
the backend and dashboard have to cope with those fields being absent.

- Feeding/Standby from status_code (FEEDING_STATUS_CODES, default 7 and 8:
  INV1's OEM board uses 7). Online but not feeding = Standby; a standby
  inverter while peers produce is still caught by the underperformance
  check. Missing error_code stays "no fault".
- Daily energy falls back to AC power integrated between readings, flagged
  estimated (≈ in the UI); out-of-order (spooled) readings recompute the
  day. Existing databases get the column and a rebuild on startup.
- Totals are null instead of 0 when there's no energy data; lifetime shows
  "not available yet". Parameters the poller doesn't send are hidden on the
  detail page, DC lines only drawn when DC data exists.
- Timestamps more than 5 min in the future are stored at receive time and
  counted in clamped_future — the example payload carried local Athens time
  labelled +00:00.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
2026-10-21 09:43:55 +03:00
co-authored by Claude Opus 5.5
parent 0b0e4b7d6d
commit d01cef991f
15 changed files with 401 additions and 82 deletions
+9
View File
@@ -189,3 +189,12 @@ export function DayBars({ days, series, format, axisFormat, height = 220 }) {
</div>
)
}
export function EnergyFootnote({ estimated }) {
return (
<div className="mt-1 flex justify-between gap-3 text-[11px] text-muted">
<span>{estimated && '≈ Estimated from AC power readings until the energy counters are decoded'}</span>
<span className="shrink-0">axis in kWh</span>
</div>
)
}