feat: match the verified on-site poller payload
The on-site agent found that the DC (P052/P054/P05A/P05C) and energy (P063) registers are static/frozen and ac_power_total_w is now computed V*I, so the backend and dashboard have to cope with those fields being absent. - Feeding/Standby from status_code (FEEDING_STATUS_CODES, default 7 and 8: INV1's OEM board uses 7). Online but not feeding = Standby; a standby inverter while peers produce is still caught by the underperformance check. Missing error_code stays "no fault". - Daily energy falls back to AC power integrated between readings, flagged estimated (≈ in the UI); out-of-order (spooled) readings recompute the day. Existing databases get the column and a rebuild on startup. - Totals are null instead of 0 when there's no energy data; lifetime shows "not available yet". Parameters the poller doesn't send are hidden on the detail page, DC lines only drawn when DC data exists. - Timestamps more than 5 min in the future are stored at receive time and counted in clamped_future — the example payload carried local Athens time labelled +00:00. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -189,3 +189,12 @@ export function DayBars({ days, series, format, axisFormat, height = 220 }) {
|
||||
</div>
|
||||
)
|
||||
}
|
||||
|
||||
export function EnergyFootnote({ estimated }) {
|
||||
return (
|
||||
<div className="mt-1 flex justify-between gap-3 text-[11px] text-muted">
|
||||
<span>{estimated && '≈ Estimated from AC power readings until the energy counters are decoded'}</span>
|
||||
<span className="shrink-0">axis in kWh</span>
|
||||
</div>
|
||||
)
|
||||
}
|
||||
|
||||