feat: match the verified on-site poller payload

The on-site agent found that the DC (P052/P054/P05A/P05C) and energy (P063)
registers are static/frozen and ac_power_total_w is now computed V*I, so
the backend and dashboard have to cope with those fields being absent.

- Feeding/Standby from status_code (FEEDING_STATUS_CODES, default 7 and 8:
  INV1's OEM board uses 7). Online but not feeding = Standby; a standby
  inverter while peers produce is still caught by the underperformance
  check. Missing error_code stays "no fault".
- Daily energy falls back to AC power integrated between readings, flagged
  estimated (≈ in the UI); out-of-order (spooled) readings recompute the
  day. Existing databases get the column and a rebuild on startup.
- Totals are null instead of 0 when there's no energy data; lifetime shows
  "not available yet". Parameters the poller doesn't send are hidden on the
  detail page, DC lines only drawn when DC data exists.
- Timestamps more than 5 min in the future are stored at receive time and
  counted in clamped_future — the example payload carried local Athens time
  labelled +00:00.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
2026-10-21 09:43:55 +03:00
co-authored by Claude Opus 5.5
parent 0b0e4b7d6d
commit d01cef991f
15 changed files with 401 additions and 82 deletions
+14 -4
View File
@@ -1,3 +1,4 @@
import logging
import secrets
import sqlite3
from datetime import date, datetime, timedelta, timezone
@@ -10,6 +11,7 @@ from .config import get_settings
from .db import get_db, set_meta
from .schemas import IngestResult, Inverter, InverterUpdate, ReadingIn, Summary
log = logging.getLogger("solar")
router = APIRouter(prefix="/api")
Db = Annotated[sqlite3.Connection, Depends(get_db)]
@@ -69,9 +71,11 @@ def post_readings(conn: Db, readings: Annotated[list[ReadingIn], Body(max_length
"""Send an empty array when no inverter answered — it still tells the
backend the datalogger is alive, which is how a dead inverter is told
apart from a dead internet link."""
stored, duplicates = store.ingest(conn, readings)
stored, duplicates, clamped = store.ingest(conn, readings)
set_meta(conn, "last_ingest_at", str(store.now_ts()))
return {"received": len(readings), "stored": stored, "duplicates": duplicates}
if clamped:
log.warning("%d readings had future timestamps (clock/timezone wrong on the poller?)", clamped)
return {"received": len(readings), "stored": stored, "duplicates": duplicates, "clamped_future": clamped}
# ---------------------------------------------------------------- dashboard
@@ -181,14 +185,20 @@ def get_inverter_daily(
end: Annotated[date | None, Query(alias="to")] = None,
days: Annotated[int, Query(ge=1, le=3660)] = 365,
):
"""Energy and peak power per local day (default: last 365 days)."""
"""Energy and peak power per local day (default: last 365 days).
`estimated` days are integrated from AC power, not the inverter's counter."""
_inverter_or_404(conn, inverter_id)
first, last = _day_range(start, end, days)
rows = store.daily_energy(conn, first, last, inverter_id)
return {
"inverter_id": inverter_id,
"days": [
{"day": r["day"], "energy_wh": r.get(inverter_id), "peak_power_w": r.get("peak_power_w")}
{
"day": r["day"],
"energy_wh": r.get(inverter_id),
"estimated": r["estimated"],
"peak_power_w": r.get("peak_power_w"),
}
for r in rows
],
}
+13
View File
@@ -44,6 +44,19 @@ class Settings(BaseSettings):
mppt_imbalance_ratio: float = 0.5
mppt_min_power_w: float = 1000.0
# status_code values that mean the inverter is feeding the grid
# (8 on the standard units, 7 on the OEM board in INV1). Any other
# reported code shows as Standby.
feeding_status_codes: list[int] = [7, 8]
# Readings stamped further than this in the future (wrong clock or local
# time sent as UTC) are stored at the time they were received instead.
max_future_skew_seconds: int = 300
# Energy is estimated by integrating AC power between consecutive
# readings; gaps longer than this are not bridged.
energy_integration_max_gap_seconds: int = 300
cors_origins: list[str] = ["*"]
@field_validator("site_latitude", "site_longitude", mode="before")
+11 -1
View File
@@ -37,6 +37,9 @@ CREATE TABLE IF NOT EXISTS daily_energy (
total_min_wh INTEGER,
total_max_wh INTEGER,
peak_power_w INTEGER,
-- AC power integrated over time: the fallback while the inverter's
-- own energy counters aren't decoded
integrated_wh REAL,
PRIMARY KEY (inverter_id, day)
) WITHOUT ROWID;
@@ -72,13 +75,20 @@ def get_db() -> Iterator[sqlite3.Connection]:
yield conn
def migrate() -> None:
def migrate() -> bool:
"""Create/upgrade the schema. Returns True when the integrated-energy
column was just added and has to be rebuilt from existing readings."""
with session() as conn:
conn.executescript(SCHEMA)
existing = {r["name"] for r in conn.execute("PRAGMA table_info(readings)")}
for f in FIELDS:
if f.key not in existing:
conn.execute(f"ALTER TABLE readings ADD COLUMN {f.key} {f.sql_type}")
daily_cols = {r["name"] for r in conn.execute("PRAGMA table_info(daily_energy)")}
if "integrated_wh" not in daily_cols:
conn.execute("ALTER TABLE daily_energy ADD COLUMN integrated_wh REAL")
return True
return False
def get_meta(conn: sqlite3.Connection, key: str) -> str | None:
+14 -2
View File
@@ -69,6 +69,9 @@ def summary(conn: sqlite3.Connection) -> dict:
spec = specific(inv) if online else None
relative = round(spec / median, 3) if spec is not None and median else None
code = r.get("status_code") if r else None
feeding = None if code is None else code in s.feeding_status_codes
if not online:
since = f"for {_minutes(r['age_seconds'])}" if r else "yet"
if not datalogger_online:
@@ -115,25 +118,34 @@ def summary(conn: sqlite3.Connection) -> dict:
})
if state == "ok" and issues:
state = "warning"
elif state == "ok" and feeding is False:
# Awake but not feeding (low light, or a state not decoded yet)
state = "standby"
statuses.append({
"inverter": inv,
"health": {
"online": online,
"feeding": feeding if online else None,
"state": state,
"issues": issues,
"avg_power_w": round(averages[inv["id"]]["ac_power_w"]) if online and averages.get(inv["id"], {}).get("ac_power_w") is not None else None,
"relative_output": relative,
},
"energy_today": energy_today.get(inv["id"], {"wh": None, "estimated": False}),
"latest": r,
})
today_values = [e["wh"] for e in energy_today.values() if e["wh"] is not None]
lifetime_values = [r["total_energy_wh"] for r in latest.values() if r.get("total_energy_wh") is not None]
totals = {
"ac_power_w": sum((latest[i["id"]].get("ac_power_total_w") or 0) for i in inverters if is_online(i["id"])),
"daily_energy_wh": sum(energy_today.values()),
"total_energy_wh": sum((r.get("total_energy_wh") or 0) for r in latest.values()),
"daily_energy_wh": sum(today_values) if today_values else None,
"daily_energy_estimated": any(e["estimated"] for e in energy_today.values() if e["wh"] is not None),
"total_energy_wh": sum(lifetime_values) if lifetime_values else None,
"inverter_count": len(inverters),
"online_count": sum(1 for i in inverters if is_online(i["id"])),
"feeding_count": sum(1 for st in statuses if st["health"]["feeding"]),
"problem_count": sum(1 for st in statuses if st["health"]["state"] in ("fault", "warning", "offline")),
}
+3 -1
View File
@@ -32,7 +32,9 @@ async def purge_loop() -> None:
@asynccontextmanager
async def lifespan(app: FastAPI):
migrate()
if migrate():
with session() as conn:
store.rebuild_integrated_energy(conn)
task = asyncio.create_task(purge_loop())
yield
task.cancel()
+18 -3
View File
@@ -49,6 +49,10 @@ class IngestResult(BaseModel):
received: int
stored: int
duplicates: int
clamped_future: int = Field(
description="Readings stamped in the future (clock wrong, or local time sent as UTC); "
"stored at the time they were received instead"
)
class InverterUpdate(BaseModel):
@@ -71,7 +75,7 @@ class Inverter(BaseModel):
Severity = Literal["info", "warning", "critical"]
State = Literal["ok", "warning", "fault", "offline", "sleeping", "unknown"]
State = Literal["ok", "standby", "warning", "fault", "offline", "sleeping", "unknown"]
class Issue(BaseModel):
@@ -82,6 +86,9 @@ class Issue(BaseModel):
class Health(BaseModel):
online: bool = Field(description="A reading arrived within ONLINE_WINDOW_SECONDS")
feeding: bool | None = Field(
description="status_code is one of FEEDING_STATUS_CODES; null when no status_code is reported"
)
state: State
issues: list[Issue]
avg_power_w: float | None = Field(description="Mean AC power over the comparison window")
@@ -90,18 +97,26 @@ class Health(BaseModel):
)
class EnergyToday(BaseModel):
wh: int | None
estimated: bool = Field(description="Integrated from AC power, not the inverter's own counter")
class InverterStatus(BaseModel):
inverter: Inverter
health: Health
energy_today: EnergyToday
latest: dict[str, Any] | None
class Totals(BaseModel):
ac_power_w: int
daily_energy_wh: int
total_energy_wh: int
daily_energy_wh: int | None
daily_energy_estimated: bool
total_energy_wh: int | None = Field(description="Null until the inverters report a lifetime counter")
inverter_count: int
online_count: int
feeding_count: int
problem_count: int
+119 -25
View File
@@ -37,26 +37,76 @@ def today() -> date:
# ---------------------------------------------------------------- ingest
def _ts_of(r: ReadingIn) -> int:
def _ts_of(r: ReadingIn, received: int) -> tuple[int, bool]:
"""Reading time in unix seconds, and whether it had to be clamped
because it lay in the future (bad clock / local time sent as UTC)."""
if r.timestamp is None:
return now_ts()
return received, False
t = r.timestamp
if t.tzinfo is None:
t = t.replace(tzinfo=timezone.utc)
return int(t.timestamp())
ts = int(t.timestamp())
if ts > received + get_settings().max_future_skew_seconds:
return received, True
return ts, False
def ingest(conn: sqlite3.Connection, readings: list[ReadingIn]) -> tuple[int, int]:
"""Store readings; returns (stored, duplicates). Re-sent readings (same
inverter + timestamp) are ignored, so the poller can safely retry."""
stored = 0
def _integrate(conn: sqlite3.Connection, inverter_id: str, ts: int, power: int | None) -> float | None:
"""Wh produced since the previous reading (trapezoid rule), or None when
there's nothing to add (no power, first reading, gap too long)."""
if power is None:
return None
prev = conn.execute(
"SELECT ts, ac_power_total_w AS w FROM readings "
"WHERE inverter_id = ? AND ts < ? ORDER BY ts DESC LIMIT 1",
(inverter_id, ts),
).fetchone()
if not prev or prev["w"] is None:
return None
dt = ts - prev["ts"]
if dt > get_settings().energy_integration_max_gap_seconds:
return None
return (prev["w"] + power) / 2 * dt / 3600
def _integrated_for_day(conn: sqlite3.Connection, inverter_id: str, day: str) -> float:
"""Integrated Wh for one inverter and local day, from scratch."""
tz = site_tz()
start = int(datetime.combine(date.fromisoformat(day), datetime.min.time(), tz).timestamp())
end = start + 2 * 86400 # covers DST days; filtered by local_day below
max_gap = get_settings().energy_integration_max_gap_seconds
rows = conn.execute(
"SELECT ts, ac_power_total_w AS w FROM readings "
"WHERE inverter_id = ? AND ts >= ? AND ts < ? ORDER BY ts",
(inverter_id, start - max_gap, end),
).fetchall()
total, prev = 0.0, None
for r in rows:
if (
prev
and prev["w"] is not None
and r["w"] is not None
and r["ts"] - prev["ts"] <= max_gap
and local_day(r["ts"]) == day
):
total += (prev["w"] + r["w"]) / 2 * (r["ts"] - prev["ts"]) / 3600
prev = r
return total
def ingest(conn: sqlite3.Connection, readings: list[ReadingIn]) -> tuple[int, int, int]:
"""Store readings; returns (stored, duplicates, clamped). Re-sent readings
(same inverter + timestamp) are ignored, so the poller can safely retry."""
stored = clamped = 0
received = now_ts()
cols = ["inverter_id", "ts", "extra", *FIELD_KEYS]
insert_sql = (
f"INSERT OR IGNORE INTO readings ({', '.join(cols)}) "
f"VALUES ({', '.join('?' for _ in cols)})"
)
for r in readings:
ts = _ts_of(r)
ts, was_clamped = _ts_of(r, received)
clamped += was_clamped
values = r.model_dump(include=set(FIELD_KEYS))
extra = {**(r.model_extra or {}), **(r.extra or {})}
@@ -76,13 +126,21 @@ def ingest(conn: sqlite3.Connection, readings: list[ReadingIn]) -> tuple[int, in
if cur.rowcount == 0:
continue
stored += 1
# A reading arriving after a later one (re-sent from the poller's
# spool out of order) changes intervals already counted: recompute
# that day instead of adding to it.
out_of_order = conn.execute(
"SELECT 1 FROM readings WHERE inverter_id = ? AND ts > ? LIMIT 1", (r.inverter_id, ts)
).fetchone() is not None
integrated_wh = None if out_of_order else _integrate(conn, r.inverter_id, ts, values["ac_power_total_w"])
# max()/min() of two values where either may be NULL
conn.execute(
"""
INSERT INTO daily_energy
(inverter_id, day, daily_energy_wh, total_min_wh, total_max_wh, peak_power_w)
VALUES (?, ?, ?, ?, ?, ?)
(inverter_id, day, daily_energy_wh, total_min_wh, total_max_wh, peak_power_w,
integrated_wh)
VALUES (?, ?, ?, ?, ?, ?, ?)
ON CONFLICT (inverter_id, day) DO UPDATE SET
daily_energy_wh = max(coalesce(daily_energy_wh, excluded.daily_energy_wh),
coalesce(excluded.daily_energy_wh, daily_energy_wh)),
@@ -91,7 +149,8 @@ def ingest(conn: sqlite3.Connection, readings: list[ReadingIn]) -> tuple[int, in
total_max_wh = max(coalesce(total_max_wh, excluded.total_max_wh),
coalesce(excluded.total_max_wh, total_max_wh)),
peak_power_w = max(coalesce(peak_power_w, excluded.peak_power_w),
coalesce(excluded.peak_power_w, peak_power_w))
coalesce(excluded.peak_power_w, peak_power_w)),
integrated_wh = coalesce(integrated_wh, 0) + coalesce(excluded.integrated_wh, 0)
""",
(
r.inverter_id,
@@ -100,9 +159,37 @@ def ingest(conn: sqlite3.Connection, readings: list[ReadingIn]) -> tuple[int, in
values["total_energy_wh"],
values["total_energy_wh"],
values["ac_power_total_w"],
integrated_wh,
),
)
return stored, len(readings) - stored
if out_of_order:
day = local_day(ts)
conn.execute(
"UPDATE daily_energy SET integrated_wh = ? WHERE inverter_id = ? AND day = ?",
(_integrated_for_day(conn, r.inverter_id, day), r.inverter_id, day),
)
return stored, len(readings) - stored, clamped
def rebuild_integrated_energy(conn: sqlite3.Connection) -> None:
"""Recompute daily integrated energy from the stored readings."""
max_gap = get_settings().energy_integration_max_gap_seconds
totals: dict[tuple[str, str], float] = {}
prev: dict[str, tuple[int, int | None]] = {}
for r in conn.execute(
"SELECT inverter_id, ts, ac_power_total_w AS w FROM readings ORDER BY inverter_id, ts"
):
p = prev.get(r["inverter_id"])
if p and p[1] is not None and r["w"] is not None and r["ts"] - p[0] <= max_gap:
key = (r["inverter_id"], local_day(r["ts"]))
totals[key] = totals.get(key, 0) + (p[1] + r["w"]) / 2 * (r["ts"] - p[0]) / 3600
prev[r["inverter_id"]] = (r["ts"], r["w"])
conn.execute("UPDATE daily_energy SET integrated_wh = NULL")
for (inv, day), wh in totals.items():
conn.execute(
"UPDATE daily_energy SET integrated_wh = ? WHERE inverter_id = ? AND day = ?",
(wh, inv, day),
)
def purge(conn: sqlite3.Connection, retention_days: int) -> int:
@@ -238,15 +325,21 @@ def fleet_power(conn: sqlite3.Connection, start: int, end: int, bucket: int) ->
return list(points.values())
# Best available energy for a day: the inverter's daily counter, else the
# lifetime counter's growth, else AC power integrated over time (estimate).
ENERGY_SQL = """
coalesce(daily_energy_wh, total_max_wh - total_min_wh, cast(round(integrated_wh) AS INTEGER)) AS wh,
(daily_energy_wh IS NULL AND total_max_wh IS NULL AND integrated_wh IS NOT NULL) AS estimated
"""
def daily_energy(
conn: sqlite3.Connection, first: date, last: date, inverter_id: str | None = None
) -> list[dict]:
"""[{day, total_wh, <inverter_id>: Wh, ...}] for every day in range, oldest first.
Uses the inverter's own daily counter, falling back to the lifetime
counter's growth over the day when the daily counter wasn't reported."""
sql = """
SELECT day, inverter_id, peak_power_w,
coalesce(daily_energy_wh, total_max_wh - total_min_wh) AS wh
"""[{day, total_wh, estimated, <inverter_id>: Wh, ...}] for every day in
range, oldest first. Days with no data have total_wh null."""
sql = f"""
SELECT day, inverter_id, peak_power_w, {ENERGY_SQL}
FROM daily_energy WHERE day >= ? AND day <= ?
"""
params: list = [first.isoformat(), last.isoformat()]
@@ -256,22 +349,23 @@ def daily_energy(
by_day: dict[str, dict] = {}
d = first
while d <= last:
by_day[d.isoformat()] = {"day": d.isoformat(), "total_wh": 0}
by_day[d.isoformat()] = {"day": d.isoformat(), "total_wh": None, "estimated": False}
d += timedelta(days=1)
for r in conn.execute(sql, params):
row = by_day[r["day"]]
row[r["inverter_id"]] = r["wh"]
row["total_wh"] += r["wh"] or 0
if r["wh"] is not None:
row["total_wh"] = (row["total_wh"] or 0) + r["wh"]
row["estimated"] = row["estimated"] or bool(r["estimated"])
if inverter_id:
row["peak_power_w"] = r["peak_power_w"]
return list(by_day.values())
def today_energy(conn: sqlite3.Connection) -> dict[str, int]:
def today_energy(conn: sqlite3.Connection) -> dict[str, dict]:
"""{inverter_id: {"wh": int | None, "estimated": bool}} for today."""
rows = conn.execute(
"SELECT inverter_id, coalesce(daily_energy_wh, total_max_wh - total_min_wh) AS wh "
"FROM daily_energy WHERE day = ?",
f"SELECT inverter_id, {ENERGY_SQL} FROM daily_energy WHERE day = ?",
(today().isoformat(),),
)
return {r["inverter_id"]: r["wh"] or 0 for r in rows}
return {r["inverter_id"]: {"wh": r["wh"], "estimated": bool(r["estimated"])} for r in rows}
+90 -1
View File
@@ -26,7 +26,9 @@ def test_rejects_missing_key(client):
def test_ingest_is_idempotent_and_keeps_unknown_fields(client):
now = int(time.time())
batch = [reading("inv1", now, 10000, p_new_param=42)]
assert client.post("/api/readings", json=batch).json() == {"received": 1, "stored": 1, "duplicates": 0}
assert client.post("/api/readings", json=batch).json() == {
"received": 1, "stored": 1, "duplicates": 0, "clamped_future": 0
}
assert client.post("/api/readings", json=batch).json()["duplicates"] == 1
latest = client.get("/api/inverters/inv1/latest").json()
@@ -100,3 +102,90 @@ def test_empty_batch_marks_datalogger_alive(client):
def test_fields_meta(client):
keys = [f["key"] for f in client.get("/api/meta/fields").json()]
assert "ac_power_total_w" in keys and "efficiency_pct" in keys
def onsite_payload(inv, ts, power=6882, status=8):
"""Exactly what the real on-site poller sends (2026-10-21)."""
return {
"timestamp": datetime.fromtimestamp(ts, timezone.utc).isoformat(),
"inverter_id": inv,
"ac_voltage_l1_v": 232.6, "ac_voltage_l2_v": 233.35, "ac_voltage_l3_v": 232.62,
"ac_current_l1_a": 11.75, "ac_current_l2_a": 9.16, "ac_current_l3_a": 8.95,
"ac_power_total_w": power, "grid_frequency_hz": 50.0, "temperature_c": 36,
"status_code": status, "status_text": "feeding" if status in (7, 8) else "standby/not feeding",
"p06d_raw_latched": 21450, "p052_static_v": 312.5, "p05a_static_a": 45.0,
"p063_ind0_raw": 1872,
}
def test_onsite_payload_accepted_and_ok(client):
now = int(time.time())
batch = [onsite_payload("INV1", now, 6900, status=7), onsite_payload("INV2", now), onsite_payload("INV4", now, 6800)]
r = client.post("/api/readings", json=batch)
assert r.status_code == 200
assert r.json() == {"received": 3, "stored": 3, "duplicates": 0, "clamped_future": 0}
s = client.get("/api/summary").json()
for st in s["inverters"]:
assert st["health"]["state"] == "ok", st
assert st["health"]["feeding"] is True
latest = s["inverters"][1]["latest"]
assert latest["extra"]["p06d_raw_latched"] == 21450
assert latest["dc_power_total_w"] is None and latest["efficiency_pct"] is None
# No energy counters sent: lifetime unknown, today not yet integrated
assert s["totals"]["total_energy_wh"] is None
assert s["totals"]["feeding_count"] == 3
def test_not_feeding_is_standby_and_flagged_when_peers_produce(client):
now = int(time.time())
client.post("/api/readings", json=[
onsite_payload("INV1", now, 6900), onsite_payload("INV2", now, 7000),
onsite_payload("INV4", now, 0, status=3),
])
by_id = {x["inverter"]["id"]: x["health"] for x in client.get("/api/summary").json()["inverters"]}
assert by_id["INV4"]["feeding"] is False
assert by_id["INV4"]["state"] == "warning" # 0 W while the others make ~7 kW
def test_all_idle_is_plain_standby(client):
# Everyone awake but not feeding (e.g. dusk): standby, no alarm
now = int(time.time())
client.post("/api/readings", json=[onsite_payload(i, now, 0, status=3) for i in ("INV1", "INV2", "INV4")])
states = {x["health"]["state"] for x in client.get("/api/summary").json()["inverters"]}
assert states == {"standby"}
def test_heartbeat(client):
r = client.post("/api/readings", json=[])
assert r.status_code == 200 and r.json()["received"] == 0
def test_future_timestamp_is_clamped(client):
now = int(time.time())
r = client.post("/api/readings", json=[onsite_payload("INV2", now + 3 * 3600)]).json()
assert r["clamped_future"] == 1
latest = client.get("/api/inverters/INV2/latest").json()
assert abs(latest["age_seconds"]) < 5
def test_energy_integrated_from_power_when_no_counters(client):
now = int(time.time())
# 6 kW for 30 minutes at 60 s steps -> 3 kWh
client.post("/api/readings", json=[onsite_payload("INV1", now - 1800 + i * 60, 6000) for i in range(31)])
s = client.get("/api/summary").json()
e = s["inverters"][0]["energy_today"]
if e["wh"] is not None: # skip when the window straddles local midnight
assert e["estimated"] is True
assert 2900 <= e["wh"] <= 3000
assert s["totals"]["daily_energy_estimated"] is True
def test_energy_survives_out_of_order_readings(client):
now = int(time.time())
# Latest reading arrives first, then the earlier ones (spool re-send)
client.post("/api/readings", json=[onsite_payload("INV1", now, 6000)])
client.post("/api/readings", json=[onsite_payload("INV1", now - 1800 + i * 60, 6000) for i in range(30)])
e = client.get("/api/summary").json()["inverters"][0]["energy_today"]
if e["wh"] is not None:
assert 2900 <= e["wh"] <= 3000