From 9d41c77668b4061be9d0d106949eb391c2097158 Mon Sep 17 00:00:00 2001 From: bonamin Date: Wed, 21 Oct 2026 09:02:12 +0300 Subject: [PATCH] docs(poller): brief for the agent building the on-site poller Co-Authored-By: Claude Opus 5.5 --- poller/ONSITE_AGENT_BRIEF.md | 72 ++++++++++++++++++++++++++++++++++++ 1 file changed, 72 insertions(+) create mode 100644 poller/ONSITE_AGENT_BRIEF.md diff --git a/poller/ONSITE_AGENT_BRIEF.md b/poller/ONSITE_AGENT_BRIEF.md new file mode 100644 index 0000000..09d740c --- /dev/null +++ b/poller/ONSITE_AGENT_BRIEF.md @@ -0,0 +1,72 @@ +# Brief: sending inverter readings to the Solar Monitor backend + +You are building (or updating) the script on the site laptop that reads the +Refusol 020K inverters over USS/TCP and reports to the backend. The backend +and dashboard already run at **https://solar.bonamin.net**. Your job is only +the on-site side: read the inverters, POST the values. + +## Files to use + +- `backend_client.py` (next to this brief): copy it next to your script and + use it to send. It's standard library only. It timestamps readings, keeps + them in `unsent_readings.jsonl` when the internet is down, re-sends them + later, and never raises. +- `README.md` (next to this brief): the field names, units and scalings. + +## What to do every 60 s + +```python +from backend_client import BackendClient + +BACKEND_URL = "https://solar.bonamin.net" +API_KEY = "" +backend = BackendClient(BACKEND_URL, API_KEY) + +while True: + readings = [] + for inv in INVERTERS: # e.g. [{"id": "INV1", "host": "192.168.1.51"}, ...] + try: + values = read_inverter(inv) # your USS code -> dict of converted values + readings.append({"inverter_id": inv["id"], **values}) + except Exception as e: + log.warning("%s not answering: %s", inv["id"], e) + # just leave it out: the dashboard marks it Offline (by day) or Sleeping (at night) + backend.send(readings) # ALWAYS call it, even with an empty list + sleep_until_next_minute() +``` + +## Rules that matter + +1. **Always call `send()`, even with an empty list.** The empty list is the + heartbeat. It's how the dashboard tells "inverter dead" (laptop still + reporting) apart from "site/internet down". +2. **`inverter_id` must stay the same forever** for each physical inverter, + e.g. `INV1`..`INV5` matching labels on the units. It's the database key. + Pretty names are set later in the dashboard, not here. Allowed characters: + letters, digits, `_ . -`. +3. **Send converted values**, not raw ones, using the keys and scalings in + `README.md` (e.g. `ac_voltage_l1_v` = P050 raw / 40). Leave out anything + you couldn't read; every field is optional. +4. **New or unconfirmed parameters:** send them too, under a descriptive key + (e.g. `p0xx_raw`). The backend stores unknown keys and shows them on the + inverter page under "Other (unmapped)". Tell the owner when a mapping is + confirmed so it gets promoted to a proper field. +5. **Fault status:** if you find the parameter holding the inverter's + state/error code, send it as `status_code` / `error_code` (non-zero + `error_code` = the dashboard shows **Fault**), with an optional + `status_text`. This is high priority: it's the most direct "is it broken?" signal. +6. A failed inverter read must never stop the loop or the other inverters. +7. Run it so it survives reboots: Windows Task Scheduler "at startup" or a + service; systemd on Linux. + +## Checking it works + +```bash +curl -X POST https://solar.bonamin.net/api/readings \ + -H "X-API-Key: " -H "Content-Type: application/json" \ + -d '[{"inverter_id":"TEST","ac_power_total_w":1234}]' +# -> {"received":1,"stored":1,"duplicates":0} +``` + +Then open https://solar.bonamin.net. The inverter appears within 30 s. +API reference: https://solar.bonamin.net/api/docs