Files
project-vesper/docs/reference
bonaminandClaude Opus 5.5 b80dbc9b89 docs(api-reference): audit against real handlers — playback.play/stop, message/data envelope, ~30 missing commands
The API reference had drifted far from the firmware. Rewritten against the
handlers' commands() lists, field parsing and CommandResult::err() strings:

- Playback: document playback.play / playback.stop (the bare v2
  cmd:"playback"+action form returns "Unknown command"; v1 form still works
  via LegacyAdapter, and is the only form UART's whitelist accepts). List the
  fields Player::setMelodyAttributes() actually parses (url, not download_url),
  how mode/duration interact, the legacy segment_duration/total_duration
  path, sticky fields, and reply type "playback".
- Response envelope: message (string) + data (object), status INFO only on
  WS broadcasts, no "payload" key; req_id is MQTT-only; v defaults per
  transport; type exceptions (pong/playback/unknown/parse_error/bad_request).
- Add missing commands: relay.set_config/test_bell/test_batch,
  clock.set_config/set_alerts_config/test_c1/test_c2, system.get_config/
  get_all/get_telemetry, ota.set_channel, log.get_config, logs.clear, all
  telemetry.* and bells.*. Remove nonexistent ota.status/ota.check.
- Fix wrong fields: clock.set_alerts is camelCase, clock.set_silence is
  nested, clock.set_time offsets need both fields, clock.set_timezone has no
  timezone_name, files.download needs download_url, ota.update defaults to
  "stable", RF play-slot fields are required (duration 0 rejected), fix legacy
  map to match LegacyAdapter.
- mqtt-events.md: fix the control/command example; note nothing calls
  CommandBus::broadcast(). Topic spec: req_id is MQTT-only today.

Doc-only — no catalog entry.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-09-29 20:02:58 +03:00
..