Player::setStatus() publishes action "stopping" when the run-time cap is reached and BellEngine is finishing the current melody loop, but the spec only listed playing/paused/idle. Kept it (not suppressed): it is a real state that can last a whole loop while bells still ring, suppressing it on MQTT alone would break WS/MQTT parity, and v1 tablets already know it. Adds a state table (entry/exit, stop/play behaviour) to mqtt-events.md and updates the topic spec and API reference. No firmware change. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
41 KiB
Vesper Firmware — API Reference (v2)
Command reference for the Vesper Bell Automation System. Firmware v2 command bus architecture — all transports, all handlers. Last updated: 2026-09-29 (full audit against the handlers'
commands()lists, field parsing and error strings). Companion docs: vesper_mqtt_topic_spec_v2.md (MQTT topics,req_id, LWT) and mqtt-events.md (unsolicited MQTT payloads). The console's API Reference page (bellsystems-cp→ApiReferencePage.jsx) mirrors this file — keep both in sync.
Overview
Message Envelope
Every command sent to Vesper uses this JSON envelope:
{
"v": 2,
"cmd": "namespace.command",
"req_id": "abc123",
"contents": { ... }
}
| Field | Type | Notes |
|---|---|---|
v |
int | Protocol version. 2 = current, 1 = legacy (runs through LegacyAdapter first — see Legacy Compatibility). If omitted, MQTT, WebSocket and UART assume 1; HTTP assumes 2. A v2 command name sent as v1 still works — the adapter leaves names it doesn't recognise unchanged. |
cmd |
string | namespace.command format (e.g. relay.set_durations). |
req_id |
string | Optional. MQTT only — echoed back on the control/ack reply for correlation. WebSocket, HTTP and UART ignore it (their replies never carry req_id). See vesper_mqtt_topic_spec_v2.md. |
contents |
object | Command payload. May be omitted if the command takes no fields. |
Response Envelope
{
"status": "SUCCESS" | "ERROR" | "INFO",
"type": "command_name",
"req_id": "abc123",
"message": "human-readable text",
"data": { ... }
}
| Field | Present when | Notes |
|---|---|---|
status |
always | SUCCESS or ERROR for command replies. INFO is only used for unsolicited broadcasts (see below) — never as a reply to a command. |
type |
always | Normally echoes the command name. Exceptions: ping → "pong"; playback.play/playback.stop → "playback"; unregistered command → "unknown"; unparseable MQTT input → "parse_error"; WebSocket/HTTP input with no cmd → "bad_request". |
req_id |
MQTT only, when the request sent one | Echoed unchanged. |
message |
text replies and every error | A plain string. |
data |
structured replies | An object (or array, for files.list_builtin). A reply carries message or data, never both. |
There is no payload field in v2 replies. payload only appears in (a) replies to legacy v1 system.status requests (translated by LegacyResponseAdapter — see system.status), and (b) unsolicited WebSocket broadcasts (status: "INFO", e.g. the playback transition event), which keep the pre-v2 shape. Unsolicited MQTT events are published on their own topics with their own shapes — see mqtt-events.md.
Unknown command (any transport):
{ "status": "ERROR", "type": "unknown", "message": "Unknown command: playback" }
Variant availability
Handlers are only registered when their dependencies exist on the build:
| Handler | Missing on | Effect |
|---|---|---|
SystemHandler (ping, identify, system.*) |
RTC-less builds (HAS_RTC=0: agnus, agnus-mini) |
Unknown command (HTTP GET /api/ping still works) |
ClockHandler (clock.*) |
RTC-less builds | Unknown command |
RFRemoteHandler (rf.*) |
builds without RF (HAS_RF=0: bespoke-rs485) |
Unknown command |
FileHandler (files.*) |
builds with no FileManager | Unknown command |
Transports
MQTT uses the v2 topic set — see vesper_mqtt_topic_spec_v2.md for the full table, per-topic ON/OFF switches, req_id correlation, and LWT.
| Transport | Address | Direction | Notes |
|---|---|---|---|
| MQTT | vesper/{device_id}/control/command |
Inbound commands | Read-only from the board's perspective. Replies go to control/ack. |
| MQTT | vesper/{device_id}/control/ack |
Outbound replies | Strictly request/response — nothing unsolicited |
| MQTT | vesper/{device_id}/control/reports |
Outbound, critical unsolicited events | e.g. bell overload — not retained |
| MQTT | vesper/{device_id}/status/heartbeat |
Outbound, retained, QoS 1 | Heartbeat every 30s + LWT |
| MQTT | vesper/{device_id}/status/playback |
Outbound, retained, QoS 1 | Playback transitions |
| MQTT | vesper/{device_id}/system/alerts |
Outbound, retained until cleared, QoS 1 | Subsystem state-change events |
| MQTT | vesper/{device_id}/system/info |
Outbound, retained, QoS 1 | Discrete device events (boot report) |
| MQTT | vesper/{device_id}/system/logs |
Outbound, QoS 0 | Mirrors serial log stream |
| MQTT | vesper/{device_id}/system/metrics |
Outbound, QoS 0 | Structured telemetry every 5 min |
| WebSocket | ws://{device_ip}/ws |
Bidirectional | Send identify on connect |
| HTTP | POST http://{device_ip}/api/command |
Request/response | Body = command envelope. Also GET /api/ping, GET /api/status (= system.status) |
| UART | Serial2 (GPIO12 TX / GPIO13 RX, 115200) | Bidirectional | LCD/button slave board. Whitelist only (below) |
| UDP | Port 32101 | Discovery | Replies to discover probes |
MQTT drops incoming commands silently (no reply) while free heap is below the publish guard (MQTTDriver::hasHeapForPublish()), and any reply is dropped if the command topic switch is off.
UART Whitelist
Only these raw cmd strings are accepted over UART; everything else is silently dropped. The check runs before legacy translation, so the v1 form must be used for playback:
ping
playback ← v1 form only: { "cmd": "playback", "contents": { "action": "play" | "stop", ... } }
clock.pause
clock.resume
system.get_time
playback.play / playback.stop sent over UART by their v2 names are not whitelisted and are dropped. UART replies never carry req_id.
WebSocket — Client Identification
WebSocket clients should send identify immediately after connecting so targeted broadcasts reach them:
{ "v": 2, "cmd": "identify", "contents": { "device_type": "master" } }
device_type: "master" (app/console) or "secondary" (slave board).
Command Reference
Unless stated otherwise every error reply is { "status": "ERROR", "type": "<cmd>", "message": "<message>" }.
Root — SystemHandler
ping
| Transports | All (RTC builds only) |
| Contents | ts (int, optional) — caller's epoch-ms; echoed back for RTT measurement |
| Returns | { "status": "SUCCESS", "type": "pong", "data": { "type": "pong", "ts": 1752600000123, "device_uptime_ms": 184213 } } (ts only if sent) |
{ "v": 2, "cmd": "ping", "contents": { "ts": 1752600000123 } }
identify
| Transports | WebSocket only |
| Contents | device_type (string, required) — "master" or "secondary" |
| Returns | { "status": "SUCCESS", "type": "identify", "message": "Device identified as master" } |
| Error | Condition |
|---|---|
identify is only available via WebSocket |
Sent over MQTT/HTTP/UART |
Missing required field: device_type |
device_type absent / not a string |
Invalid device_type. Use 'master' or 'secondary' |
Any other value |
Playback — PlaybackHandler
The registered commands are playback.play and playback.stop. There is no v2 cmd: "playback" with an action field — see Bare playback command below.
Both commands reply with type: "playback" (not the command name).
playback.play
| Transports | MQTT, WebSocket, HTTP (UART: v1 form only) |
| Returns | { "status": "SUCCESS", "type": "playback", "message": "Playback command executed" } |
The SUCCESS reply means the board accepted the command, not that bells are ringing. status/playback (MQTT) is the source of truth for what the board is actually doing — playing / paused / stopping / idle; see mqtt-events.md → States.
Fields are sticky. Every field except mode/continuous_loop keeps the value from the previous playback.play (or its boot default) when omitted — including pid, url, speed and the tail of note_assignments. Send every field you care about on every play.
| Field | Type | Required | Notes |
|---|---|---|---|
pid |
string | yes* | Melody ID. Looked up in the built-in library, then /melodies/{pid} on SD, then downloaded from url. *If omitted, the previous pid is reused; the command fails if that is empty. |
uid |
string | no | Alias for pid, read only when pid is absent. |
name |
string | no | Display name. Informational only. |
url |
string | no | Download URL, used only when the melody is not built-in and not on SD. The field is url — download_url is not read by playback.play (that name belongs to files.download). Sticky: a URL from an earlier play is reused if omitted. |
speed |
int | no | ms per beat. Boot default 500. 0 is coerced to 300. |
note_assignments |
int[] | no | Up to 16 entries. Index = melody note (0-based), value = 1-based bell channel to ring for that note, 0 = silent. Boot default [1,2,…,16]. Entries past 16 are ignored; a shorter array leaves the remaining entries at their previous values. |
mode |
string | no | "single" | "timed" | "interval" | "infinite". Unrecognised values behave as "single". Selects the timing model — see below. |
duration |
int | no | ms. Read only when mode is present. |
pause_duration |
int | no | ms between segments. Read when mode is "interval", or when mode is absent. |
total_duration |
int | no | ms. Read when mode is "interval", or (with continuous_loop: true) when mode is absent. |
segment_duration |
int | no | ms. Legacy — read only when mode is absent. |
continuous_loop |
bool | no | Legacy — read only when mode is absent. Defaults to false on every command (not sticky). |
How mode and duration interact (mode present — segment_duration and continuous_loop are ignored):
mode |
Behaviour | Fields read |
|---|---|---|
"single" |
Play the melody once, then stop. | — (duration ignored) |
"timed" |
Loop the melody; when duration ms have elapsed, finish the current loop and stop (status goes stopping → idle). duration: 0 behaves like single. |
duration |
"interval" |
Play for duration ms, pause pause_duration ms, repeat; stop after total_duration ms overall (0 = forever). |
duration, pause_duration, total_duration |
"infinite" |
Loop until playback.stop. |
— |
Legacy timing (mode absent):
continuous_loop |
Behaviour |
|---|---|
false / absent |
Run for segment_duration ms (sticky, boot default 15000), finish the loop, stop. total_duration is ignored — it is overwritten with segment_duration. segment_duration: 0 plays the melody once. |
true |
Segments of segment_duration ms separated by pause_duration ms. Stops after total_duration ms if given in this command, else after segment_duration if that was given, else the previous total_duration. Total 0 = forever. |
| Error | Condition |
|---|---|
Playback command failed |
Any rejection: playback already active (playing / paused / stopping — send playback.stop first); pid empty or "-"; melody file on SD could not be loaded; melody not built-in/on SD and no url |
Known gaps in current firmware (addressed separately — see the feature catalog): when a download is needed the reply is SUCCESS and a failed download is only logged; with bells.disable in effect the command succeeds and status reports playing but no bell rings.
{ "v": 2, "req_id": "a1", "cmd": "playback.play", "contents": { "pid": "westminster", "speed": 400, "mode": "single" } }
{ "v": 2, "cmd": "playback.play", "contents": { "pid": "ABC123", "url": "https://example.com/ABC123.bin", "mode": "timed", "duration": 120000 } }
{ "v": 2, "cmd": "playback.play", "contents": { "pid": "ABC123", "mode": "interval", "duration": 15000, "pause_duration": 5000, "total_duration": 180000 } }
{ "v": 2, "cmd": "playback.play", "contents": { "pid": "ABC123", "segment_duration": 15000, "pause_duration": 5000, "continuous_loop": true } }
playback.stop
| Transports | MQTT, WebSocket, HTTP (UART: v1 form only) |
| Contents | (none) |
| Returns | { "status": "SUCCESS", "type": "playback", "message": "Playback command executed" } |
Stops immediately (bells are cut mid-loop, status goes straight to idle). Sending it while already idle also returns SUCCESS with the same message.
{ "v": 2, "cmd": "playback.stop" }
Bare playback command
| Request | Result |
|---|---|
{ "cmd": "playback", "contents": { "action": "play", ... } } with v omitted or 1 |
Works — LegacyAdapter maps it to playback.play (strips action) |
same with "action": "stop" |
Works — mapped to playback.stop |
"action": "pause" / "unpause" / anything else |
Unknown command: playback |
{ "v": 2, "cmd": "playback", ... } |
Unknown command: playback |
over HTTP without v |
Unknown command: playback (HTTP defaults to v2) |
Relay Namespace — RelayHandler
Bell channels are 0-based ("0".."15"). Relay output numbers in config are 1-based (1 = first relay, 0 = disabled) — except relay.test_output, which takes a raw 0-based chip pin.
relay.set_durations
Set strike duration (ms) for one or more bell channels. Partial updates accepted.
| Contents | bells (object) — { "0": 95, "2": 110 }. v1 flat form ({ "b1": 95 } at the top level) also accepted. |
| Returns | message: "Bell durations updated and saved" |
| Error | Condition |
|---|---|
Missing or invalid 'bells' object |
contents is empty/absent |
Durations updated but failed to save to SD |
Applied in RAM, SD write failed |
{ "v": 2, "cmd": "relay.set_durations", "contents": { "bells": { "0": 95, "1": 100, "2": 110 } } }
relay.set_outputs
Map bell channels to relay outputs (1-based, 0 = disabled). Partial updates accepted. Same shape and errors as relay.set_durations (Outputs updated but failed to save to SD). Returns message: "Bell outputs updated and saved".
{ "v": 2, "cmd": "relay.set_outputs", "contents": { "bells": { "0": 1, "1": 2, "2": 3 } } }
relay.set_config
Durations and/or outputs in one command.
| Contents | durations (object, optional), outputs (object, optional) — at least one |
| Returns | message: "Bell configuration updated and saved" |
| Error | Condition |
|---|---|
Provide 'durations' and/or 'outputs' objects |
Neither present |
Durations applied but failed to save to SD |
SD write failed |
Outputs applied but failed to save to SD |
SD write failed |
relay.get_config
| Returns | data: { "durations": { "0": 95, ... }, "outputs": { "0": 1, ... } } |
relay.test_output
Fire a raw chip output for a caller-specified duration.
| Contents | output (int, required, 0-based chip pin 0–31), duration_ms (int, required, 1–5000) |
| Returns | message: "Output 2 fired for 95 ms" |
| Error | Condition |
|---|---|
Missing required field: output |
|
Missing required field: duration_ms |
|
Player must be stopped before testing outputs |
Player not idle |
output must be 0-31 |
|
duration_ms must be 1-5000 |
relay.test_bell
Fire bell channel N on its configured output for its configured duration. Bypasses bells.disable.
| Contents | bell (int, required, 0–15) |
| Returns | data: { "bell": 0, "output": 1, "duration_ms": 95 } (output 1-based) |
| Error | Condition |
|---|---|
Missing required field: bell (0-based bell index) |
|
bell must be 0-15 |
|
Bell <n> is disabled or unconfigured |
Bell has no output assigned |
relay.test_batch
Fire several bell channels at once. Bypasses bells.disable.
| Contents | bells (int[], required) — 0-based channels; out-of-range, non-integer and unconfigured entries are skipped |
| Returns | data: { "fired": 3 } |
| Error | Condition |
|---|---|
Missing required field: bells (array of 0-based bell indices) |
|
bells array must not be empty |
|
No valid bell indices in array |
Nothing was fired |
Clock Namespace — ClockHandler (RTC builds only)
Every set_* below except set_time/set_face/set_timezone can also fail with Updated but failed to save to SD (or the command-specific save message listed).
clock.set_outputs
| Contents | c1 (int), c2 (int), pulseDuration (int), pauseDuration (int) — all optional; unknown/missing fields are silently ignored (no "nothing to do" error) |
| Returns | message: "Clock outputs updated and saved" |
clock.set_timings
| Contents | pulse_duration (int), pause_duration (int) — at least one |
| Returns | message: "Clock timings updated and saved" |
| Error | No timing fields provided (pulse_duration, pause_duration) |
clock.set_alerts
Field names are camelCase (they go straight to ConfigManager::updateClockAlerts()); snake_case names are silently ignored. Use clock.set_alerts_config for the snake_case form.
| Contents | alertType ("OFF"/"SINGLE"/"HOURS"), alertRingInterval (int), hourBell, halfBell, quarterBell (int, 1-based bell, 255 = disabled) — all optional |
| Returns | message: "Clock alerts updated and saved" |
clock.set_backlight
| Contents | backlight (bool), backlight_output (int), backlight_on / backlight_off ("HH:MM") — all optional |
| Returns | message: "Clock backlight updated and saved" |
clock.set_silence
Nested shape — flat snake_case fields are silently ignored (use clock.set_alerts_config for those):
{ "v": 2, "cmd": "clock.set_silence", "contents": {
"daytime": { "enabled": false, "onTime": "12:00", "offTime": "14:00" },
"nighttime": { "enabled": true, "onTime": "22:00", "offTime": "07:00" } } }
Returns message: "Clock silence periods updated and saved".
clock.set_config
| Contents | enabled (bool), c1, c2 (int, 1-based output, 0 = disabled), pulse_duration, pause_duration (int) — at least one |
| Returns | message: "Clock configuration updated and saved" |
| Error | Condition |
|---|---|
Provide at least one field: enabled, c1, c2, pulse_duration, pause_duration |
|
Settings applied but failed to save to SD |
clock.set_alerts_config
Snake_case alerts + silence in one command.
| Contents | alert_type, alert_interval, hour_bell, half_bell, quarter_bell, daytime_silence, daytime_on, daytime_off, night_silence, night_on, night_off — at least one |
| Returns | message: "Clock alerts and silence configuration updated and saved" |
| Error | Condition |
|---|---|
Provide at least one of: alert_type, alert_interval, hour_bell, half_bell, quarter_bell, daytime_silence, daytime_on, daytime_off, night_silence, night_on, night_off |
|
Settings applied but failed to save to SD |
clock.set_time
| Contents | timestamp (int, required, Unix epoch UTC), timezone_offset + dst_offset (int, seconds) |
| Returns | message: "RTC time updated successfully" |
timezone_offset (total UTC offset incl. DST) and dst_offset are only applied when both are present — they also update the stored timezone. With only one (or neither), timestamp is written to the RTC as-is.
| Error | Condition |
|---|---|
Missing required field: timestamp |
|
Invalid timestamp value |
timestamp is 0 |
RTC time set but verification failed |
RTC read-back returned 0 |
{ "v": 2, "cmd": "clock.set_time", "contents": { "timestamp": 1740000000, "timezone_offset": 10800, "dst_offset": 3600 } }
clock.set_face
| Contents | hour (0–23), minute (0–59) — both required |
| Returns | message: "Physical clock face updated and saved" |
Errors: Missing required fields: hour, minute, hour must be 0-23, minute must be 0-59, Face set but failed to save to SD.
clock.set_timezone
| Contents | gmt_offset_sec (int, required), dst_offset_sec (int, optional, default 0) |
| Returns | message: "Timezone updated and saved" |
Errors: Missing required field: gmt_offset_sec, Timezone updated but failed to save to SD.
clock.get_timezone
Returns data: { "gmt_offset_sec": 7200, "dst_offset_sec": 3600, "ntp_server": "pool.ntp.org" }.
clock.sync_ntp
Runs an NTP sync (blocking up to ~5 s). Returns message: "NTP sync initiated" regardless of outcome.
clock.enable / clock.disable
Returns message: "Clock enabled and saved" / "Clock disabled and saved". Errors: Enabled but failed to save to SD / Disabled but failed to save to SD.
clock.pause / clock.resume
Returns message: "Clock updates paused" / "Clock updates resumed".
clock.get_face
Returns data: { "clock_hour", "clock_minute", "last_sync_time", "next_output_is_c1" }.
clock.get_config
Returns data: { "enabled", "c1output", "c2output", "pulse_duration", "pause_duration", "physical_hour", "physical_minute", "next_is_c1", "last_sync_time", "alert_type", "alert_interval", "hour_bell", "half_bell", "quarter_bell", "backlight", "backlight_output", "backlight_on", "backlight_off", "daytime_silence", "daytime_on", "daytime_off", "night_silence", "night_on", "night_off", "gmt_offset_sec", "dst_offset_sec", "ntp_server" } (bells 1-based, 255 = disabled).
clock.test_c1 / clock.test_c2
Fire C1/C2 for the configured pulse. Returns data: { "output": "C1", "duration_ms": 100 }. Error: OutputManager not available.
System Namespace — SystemHandler (RTC builds only)
system.status
Returns data: { "player_status": "PLAYING"|"PAUSED"|"STOPPING"|"STOPPED", "time_elapsed_ms", "projected_run_time", "strike_counters": { "0": 1234, ... } }.
A v1 request (no v, or v:1) gets the reply translated by LegacyResponseAdapter: type: "current_status", fields under payload (not data), lowercase player_status (playing/paused/stopping/idle), time_elapsed (ms), strike_counters as an array.
system.get_time
Returns data: { "local_timestamp", "utc_timestamp", "rtc_available", "year", "month", "day", "hour", "minute", "second" }.
system.get_config (alias system.get_settings)
Full ConfigManager dump plus general: { bells_enabled, mqtt_enabled, ota_channel, serial_log, sd_log, mqtt_log }. Error: Failed to serialize settings.
system.get_all
Returns data: { "device": { serial, hw_family, hw_revision, fw_version, uptime_ms, free_heap }, "config": {...}, "telemetry": {...}, "player": { "status": "PLAYING"|"PAUSED"|"STOPPING"|"STOPPED" } }.
system.get_telemetry
Returns data: { strikes, loads, max_loads, cooling_active, guard_enabled, lifetime_runtime_seconds, session_runtime_seconds, total_playbacks, lifetime_boot_count, uptime_ms, free_heap }.
system.get_device_info
Returns data: { "uid", "hw_type", "hw_version", "fw_version", "uptime_ms", "free_heap", "min_free_heap" }.
system.health
Returns data: { "critical_count", "warning_count", "firmware_stable", "subsystems": [ { "name", "status": "HEALTHY"|"WARNING"|"CRITICAL"|"FAILED", "error"? } ] }.
system.factory_reset
Warning: Non-reversible. All saved configuration is wiped. Restart to apply.
Returns message: "Factory reset complete. Restart device to apply.". Error: Factory reset partially applied — some settings may not have saved.
system.restart
Returns message: "Device will restart in 2 seconds", then reboots.
system.set_identity
Overwrite the device's factory-set identity (serial, hw_family, hw_revision) in NVS and reboot to apply it. Sysadmin use only, via the backend console, which must update its own device record (including re-deriving the MQTT password from the new serial) in the same operation.
Warning: A serial mismatch with the backend record breaks MQTT auth; a wrong
hw_family/hw_revisioncan pull the wrong OTA build. Restarts 2 s after a successful reply.
| Transports | MQTT only |
| Contents | serial, hw_family, hw_revision (all required strings) |
| Returns | message: "Device identity updated. Restarting in 2 seconds to apply." |
| Error | Condition |
|---|---|
system.set_identity is only available via MQTT |
Sent over WebSocket, HTTP, or UART |
Missing required fields: serial, hw_family, hw_revision (all required) |
Any field absent or not a string |
serial, hw_family and hw_revision must be non-empty |
Any field empty |
Failed to persist new identity to NVS — device identity unchanged |
NVS write failed |
Firmware Namespace — FirmwareHandler
firmware.status
Returns data: { "validation_state", "current_version", "is_testing", "is_valid", "boot_count", "build_date", "ota_channel", "startup_retry_count", "max_startup_retries", "runtime_failure_count", "max_runtime_failures", "backup_version", "backup_is_valid", "can_commit", "can_rollback", "runtime_timeout_ms"? } (runtime_timeout_ms only while testing).
firmware.commit
Returns message: "Firmware committed successfully". Errors: No firmware validation in progress, Failed to commit firmware.
firmware.rollback
Warning: Device reboots.
Returns message: "Firmware rollback initiated — device will reboot". Error: Failed to initiate firmware rollback.
OTA Namespace — FirmwareHandler
There are no ota.status / ota.check commands — OTA state is in firmware.status, telemetry.get_diagnostics and system/metrics.
ota.update
Warning: Device reboots after flashing.
| Contents | channel (string, optional) — defaults to "stable" when omitted (not the channel saved with ota.set_channel) |
| Returns | message: "OTA update started from channel: stable" |
| Error | Cannot update while playback is active (only checked while PLAYING) |
ota.custom
Warning: Device reboots after flashing.
| Contents | firmware_url (string, required), checksum (string), file_size (int), version (string) |
| Returns | message: "Custom OTA update started" |
Errors: Missing required field: firmware_url, Cannot update while playback is active.
ota.set_channel
Persists the OTA channel used by the scheduled update check.
| Contents | channel (string, required) — stable / beta / development |
| Returns | data: { "channel": "beta" } |
Errors: Missing required field: channel, Invalid channel. Valid values: stable, beta, development.
Network Namespace — NetworkHandler
network.info
Returns data: { "ip", "subnet", "gateway", "dns", "mac", "hostname", "ssid", "connection_type": "WIFI"|"ETHERNET"|"AP" }.
network.status
Returns data: { "connected", "ap_mode", "rssi", "uptime_ms", "state" }.
network.set_config
Partial update; restart required to apply.
| Contents | hostname (string), useStaticIP (bool), ip, gateway, subnet, dns1, dns2 (strings), permanent_ap_mode (bool) |
| Returns | message: "Network configuration saved. Restart device to apply changes." — or, when permanent_ap_mode is sent (all other fields are then ignored), "AP mode saved. Restart to apply." / "Station mode saved. Restart to apply." |
| Error | Condition |
|---|---|
No network parameters provided |
None of hostname, useStaticIP, permanent_ap_mode present |
Hostname must be 1-32 characters |
|
Static IP requires: ip, gateway, subnet |
useStaticIP: true without all three |
Invalid IP address format / Invalid gateway format / Invalid subnet format |
Files Namespace — FileHandler
files.list
Returns data: { "files": [ ... ] } — melody files in /melodies on SD. Error: Failed to read melody list.
files.list_builtin
Returns data: [ { "name": "...", "pid": "..." }, ... ] (an array). Error: Failed to read built-in melody list.
files.download
Download a melody to /melodies/{melodys_uid} on SD. Built-in melodies are skipped (reported as success).
| Contents | download_url (string, required), melodys_uid (string, required) |
| Returns | message: "Melody downloaded: <uid>" |
| Error | Failed to download melody: <uid> — either field missing, HTTP/SD failure |
{ "v": 2, "cmd": "files.download", "contents": { "melodys_uid": "ABC123", "download_url": "https://example.com/ABC123.bin" } }
files.delete
| Contents | name (string, required) |
| Returns | message: "Melody deleted: <name>" |
Errors: Missing required field: name, Failed to delete melody: <name>.
Log Namespace — LoggingHandler
Level 0 = none, 1 = error, 2 = warning, 3 = info, 4 = debug, 5 = verbose.
log.set_serial / log.set_sd / log.set_mqtt
| Contents | level (int 0–5, required) |
| Returns | message: "serial log level set to 3 and saved" (channel name varies) |
Errors: Missing or invalid 'level' (0-5 required), Invalid log level (must be 0-5), Level applied but failed to save to SD.
log.get_config
Returns data: { "serial_level", "sd_level", "mqtt_level" }.
logs.list
Day-rotated SD log files. Returns data: { "files": [ { "name": "2026-07-14.log", "size": 1234 } ] }.
Errors: SD card not available on this device, Failed to read log directory.
logs.download
Read ≤4096 bytes of a log file; loop with next_offset until eof.
| Contents | file (string, required, bare filename), offset (int, default 0) |
| Returns | data: { "file", "data", "next_offset", "eof" } |
Errors: SD card not available on this device, Missing required field: file, Log file not found: <file>.
logs.clear
Warning: Deletes all SD debug log files.
Returns data: { "deleted": 4 }. Error: SD card not available on this device.
RF Remote Namespace — RFRemoteHandler (HAS_RF builds only)
Up to 16 slots, each binding one 433 MHz code to a playback action. Slots are blank by default. Stored in NVS namespace rf.
Slot object
| Field | Type | Required | Notes |
|---|---|---|---|
slot |
int | yes | 0–15 |
rf_code |
uint32 | yes | Must be non-zero |
is_stop |
bool | no | Default false. If true, the code force-stops playback; the fields below are ignored. |
pid |
string | yes (play) | Built-in or SD melody ID |
speed |
int | yes (play) | ms per beat, non-zero |
duration |
int | yes (play) | ms, non-zero. The slot plays like legacy segment_duration: loop for duration ms, finish the loop, stop. |
note_assignments |
int[16] | yes (play) | Exactly 16 entries, at least one non-zero. Index = note, value = 1-based bell, 0 = silent. |
rf.set_slot
Single slot (fields at top level) or batch ({ "slots": [ ... ] }).
| Returns | message: "Slot 0 programmed" or "3 slot(s) programmed" |
| Error (single form) | Condition |
|---|---|
missing 'slot' |
|
'slot' out of range (got <n>, must be 0–15) |
|
slot <n>: missing or zero 'rf_code' |
|
slot <n>: play slot missing 'pid' |
|
slot <n>: play slot missing 'speed' / slot <n>: 'speed' must be non-zero |
|
slot <n>: play slot missing 'duration' / slot <n>: 'duration' must be non-zero |
|
slot <n>: play slot missing 'note_assignments' |
|
slot <n>: 'note_assignments' must have exactly 16 elements (got <k>) |
|
slot <n>: 'note_assignments' are all zero — no bells would ring |
Batch form wraps the same reason: Slot entry invalid — <reason>. No slots were saved. — note: entries before the invalid one have in fact already been saved despite the wording.
{ "v": 2, "cmd": "rf.set_slot", "contents": { "slot": 0, "rf_code": 9274392, "pid": "vesper_fst_1_4", "speed": 500, "duration": 60000, "note_assignments": [1,2,3,4,5,6,0,0,0,0,0,0,0,0,0,0] } }
{ "v": 2, "cmd": "rf.set_slot", "contents": { "slots": [ { "slot": 7, "rf_code": 9274385, "is_stop": true } ] } }
rf.clear_slot
| Contents | slot — int 0–15 or "all" |
| Returns | message: "Slot 3 cleared" / "All slots cleared" |
Errors: Invalid value for 'slot' — use a slot index (0–15) or "all", Required: 'slot' — slot index (0–15) or "all", Invalid slot index — must be 0–15.
rf.get_slots
{
"status": "SUCCESS",
"type": "rf.get_slots",
"data": {
"enabled": true,
"slots": [
{ "slot": 0, "empty": false, "rf_code": 9274392, "pid": "vesper_fst_1_4", "speed": 500, "duration": 60000, "is_stop": false,
"note_assignments": [1,2,3,4,5,6,0,0,0,0,0,0,0,0,0,0] },
{ "slot": 1, "empty": true, "rf_code": 0, "pid": "", "speed": 0, "duration": 0, "is_stop": false, "note_assignments": [0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0] }
]
}
}
rf.enable
| Contents | enabled (bool, required) |
| Returns | message: "RF remote enabled" / "RF remote disabled" |
| Error | Required: 'enabled' (bool) |
MQTT Namespace — MQTTHandler
mqtt.enable / mqtt.disable
Master switch. mqtt.enable connects; mqtt.disable publishes the offline heartbeat, then disconnects.
Returns message: "MQTT enabled and saved" / "MQTT disabled and saved". Error: MQTT state changed but failed to save to SD.
mqtt.get_config
Returns data: { "enabled", "host", "port", "user", "use_ssl" } (never the password).
mqtt.get_topics
Returns data: { "command", "heartbeat", "playback", "reports", "alerts", "info", "logs", "metrics" } (bools).
mqtt.set_topics
Partial update — any of the 8 switch names as bools, at least one.
Returns message: "MQTT topic switches updated and saved".
| Error | Condition |
|---|---|
No recognised topic fields in contents (command, heartbeat, playback, reports, alerts, info, logs, metrics) |
|
Topic switches changed but failed to save to SD |
Telemetry Namespace — TelemetryHandler
| Command | Contents | Returns | Errors |
|---|---|---|---|
telemetry.get_strikes |
— | data: { "strikes": { "0": 1234, ... } } |
— |
telemetry.reset_strikes |
bell (ignored — always resets all) |
message: "All strike counts reset" |
— |
telemetry.get_loads |
— | data: { "loads", "max_loads", "cooling_active", "guard_enabled", "overloaded": [0-based channels] } |
— |
telemetry.set_max_loads |
all (int > 0) or loads ({ "0": 300 }; zero/out-of-range entries skipped) |
message: "All bell max loads updated" / "Bell max loads updated" |
max_load must be > 0, Provide 'all' (uint16) or 'loads' (object) |
telemetry.set_guard_enabled |
enabled (bool, required) |
message: "Bell guard enabled" / "... disabled" |
Missing required field: enabled (bool) |
telemetry.get_metrics |
— | data: { lifetime_runtime_seconds, session_runtime_seconds, total_playbacks, guard_enabled, lifetime_boot_count } |
— |
telemetry.reset_metrics |
— | message: "Lifetime runtime and playback count reset to zero" |
— |
telemetry.get_boot_history |
limit (int, optional; clamped to 1–200, 0 → 1, omitted → 200) |
data: { "count", "boots": [...] } |
No boot history available (no SD card, or no boot has completed NTP sync yet) |
telemetry.get_diagnostics |
— | data: { cpu_temp?, wifi_reconnects, ota, stack_high_water } (non-consuming peek of the system/metrics report) |
— |
telemetry.reset_boot_data |
— | message: "Lifetime boot count and SD boot log reset" |
Failed to reset lifetime boot count in NVS |
Bells Namespace — BellsHandler
Master switch for the bell mechanism (BellEngine playback and clock alerts). relay.test_* bypass it.
| Command | Returns | Error |
|---|---|---|
bells.enable |
message: "Bell mechanism enabled and saved" |
Bell mechanism enabled but failed to save to SD |
bells.disable |
message: "Bell mechanism disabled and saved" |
Bell mechanism disabled but failed to save to SD |
bells.get_config |
data: { "bells_enabled", "durations", "outputs" } |
— |
MQTT Events (Unsolicited)
Published without a request, on the v2 topic set. Full field-level reference: mqtt-events.md.
| Topic | When | QoS | Retained | Switch |
|---|---|---|---|---|
vesper/{id}/status/heartbeat |
Every 30s (+ LWT on unclean disconnect) | 1 | yes | heartbeat |
vesper/{id}/status/playback |
On playback transition | 1 | yes | playback |
vesper/{id}/control/reports |
Critical unsolicited events (e.g. bell overload) | 1 | no | reports |
vesper/{id}/system/alerts |
On subsystem state change only | 1 | yes, until cleared | alerts |
vesper/{id}/system/info |
Discrete device events (e.g. boot report) | 1 | yes | info |
vesper/{id}/system/logs |
Mirrors serial log stream | 0 | no | logs |
vesper/{id}/system/metrics |
Every 5 min | 0 | no | metrics |
control/ack carries only replies (it is not an event topic).
Legacy Compatibility (v1)
When v is 1 (or omitted on MQTT/WebSocket/UART), LegacyAdapter rewrites cmd + contents.action to a v2 command (removing action) before dispatch. A cmd it doesn't recognise is passed through unchanged, so v2 command names still work without v. Only system.status replies are translated back to the v1 shape (see system.status).
v1 cmd |
v1 action |
v2 cmd |
|---|---|---|
ping |
— | ping |
identify |
— | identify |
playback |
play |
playback.play |
playback |
stop |
playback.stop |
file_manager |
list_melodies |
files.list |
file_manager |
download_melody |
files.download |
file_manager |
delete_melody |
files.delete |
relay_setup |
set_timings |
relay.set_durations |
relay_setup |
set_outputs |
relay.set_outputs |
clock_setup |
set_outputs |
clock.set_outputs |
clock_setup |
set_timings |
clock.set_timings |
clock_setup |
set_alerts |
clock.set_alerts |
clock_setup |
set_backlight |
clock.set_backlight |
clock_setup |
set_silence |
clock.set_silence |
clock_setup |
set_rtc_time |
clock.set_time |
clock_setup |
set_physical_clock_time |
clock.set_face |
clock_setup |
pause_clock_updates |
clock.pause |
clock_setup |
resume_clock_updates |
clock.resume |
clock_setup |
set_enabled + enabled=true |
clock.enable |
clock_setup |
set_enabled + enabled=false |
clock.disable |
system_info |
report_status |
system.status |
system_info |
get_device_time |
system.get_time |
system_info |
get_clock_time |
clock.get_face |
system_info |
get_firmware_status |
firmware.status |
system_info |
network_info |
network.info |
system_info |
get_full_settings |
system.get_config |
system_info |
get_all_settings |
system.get_all |
system_info |
get_telemetry |
system.get_telemetry |
system_info |
sync_time_to_lcd |
system.get_time (LCD now uses request/response) |
bells |
enable |
bells.enable |
bells |
disable |
bells.disable |
bells |
get_config |
bells.get_config |
system |
status |
system.status |
system |
reset_defaults |
system.factory_reset |
system |
commit_firmware |
firmware.commit |
system |
rollback_firmware |
firmware.rollback |
system |
get_firmware_status |
firmware.status |
system |
set_network_config |
network.set_config |
system |
set_serial_log_level |
log.set_serial |
system |
set_sd_log_level |
log.set_sd |
system |
set_mqtt_log_level |
log.set_mqtt |
system |
set_mqtt_enabled + enabled=true |
mqtt.enable |
system |
set_mqtt_enabled + enabled=false |
mqtt.disable |
system |
restart |
system.restart |
system |
reboot |
system.restart |
system |
force_update |
ota.update |
system |
custom_update |
ota.custom |
Quick Reference
| Namespace | Commands |
|---|---|
| (root) | ping, identify |
playback |
play, stop |
relay |
set_durations, set_outputs, set_config, get_config, test_output, test_bell, test_batch |
clock |
set_outputs, set_timings, set_alerts, set_backlight, set_silence, set_config, set_alerts_config, set_time, set_face, set_timezone, get_timezone, sync_ntp, enable, disable, pause, resume, get_face, get_config, test_c1, test_c2 |
system |
status, get_time, get_config (alias get_settings), get_all, get_telemetry, get_device_info, health, factory_reset, restart, set_identity |
firmware |
status, commit, rollback |
ota |
update, custom, set_channel |
network |
info, status, set_config |
files |
list, list_builtin, download, delete |
log / logs |
log.set_serial, log.set_sd, log.set_mqtt, log.get_config, logs.list, logs.download, logs.clear |
mqtt |
enable, disable, get_config, get_topics, set_topics |
telemetry |
get_strikes, reset_strikes, get_loads, set_max_loads, set_guard_enabled, get_metrics, reset_metrics, get_boot_history, get_diagnostics, reset_boot_data |
bells |
enable, disable, get_config |
rf |
set_slot, clear_slot, get_slots, enable (HAS_RF builds only) |