feat(Telemetry,Networking,OTAManager,CommunicationRouter): diagnostics report — CPU temp, WiFi reconnects, OTA state, stack high-water mark

Console requested four more Health-tab metrics beyond F-054's free_heap/ping
work. None needed 30s heartbeat freshness, so this adds a separate low-frequency
report instead of growing the heartbeat further: published every 5 min to
status/info (diagnostics_report) and queryable on-demand via a new
telemetry.get_diagnostics command.

Only CPU temperature needs local sampling (15s, via a min/max/avg RunningStats
accumulator on Telemetry) — a thermal spike could occur and subside entirely
within a 5-minute gap. The other three fields are monotonic/self-tracking
(WiFi reconnect counter, FreeRTOS's own stack high-water mark, rarely-changing
OTA state) so a single read at report time loses no information.

Verified: pio run on all four board variants.
This commit is contained in:
2026-07-17 13:09:16 +03:00
parent 9cd6b142ef
commit 959cb77d81
14 changed files with 388 additions and 9 deletions
@@ -137,5 +137,16 @@ If any required reference is null when `registerHandlers()` runs (inside `begin(
}
```
`boot_count` is `Telemetry::getLifetimeBootCount()` — see [Telemetry's Boot tracking section](../../Telemetry/README.md#boot-tracking) for why this is a separate counter from `FirmwareValidator`'s NVS `boot_count`. The `crash` object is present only when a coredump was found for the crash that caused this boot (`CrashReport::available == true`) — omitted entirely on a clean/expected reset, or when no coredump was captured for a fault reset (e.g. a brownout, which doesn't produce one).
- **Diagnostics reporting**: `loop()` calls `reportDiagnosticsIfDue()` every main-loop iteration, which no-ops until `DIAGNOSTICS_REPORT_INTERVAL_MS` (5 minutes, `Telemetry.hpp`) has elapsed and `_telemetry` is set. Unlike `reportBootOnce()` (a one-shot MQTT-onConnect callback), this is a plain `millis()`-diff check — same style as `Telemetry`'s own `RUNTIME_FLUSH_INTERVAL_MS` check — so it fires on a fixed wall-clock cadence regardless of MQTT connection churn (a no-op `publishInfo()` call if disconnected, same as any other info event). Publishes a consolidated `"diagnostics_report"` event to `vesper/{uid}/status/info`:
```json
{
"type": "diagnostics_report",
"cpu_temp": { "avg": 47.1, "min": 44.8, "max": 52.8, "samples": 20 },
"wifi_reconnects": { "lifetime_count": 2, "last_reason": "AUTH_EXPIRE", "last_at_uptime_ms": 3600000 },
"ota": { "current_version": "2.7.3", "update_available": false, "last_check_uptime_ms": 180000, "last_error": "NONE" },
"stack_high_water": { "TelemetryTask": 1024, "HealthMonitor": 890 }
}
```
`cpu_temp` pulls from `Telemetry::writeTemperatureStats()` then calls `resetDiagnosticsStats()` — the accumulator is consumed on the periodic path (unlike the on-demand `telemetry.get_diagnostics` command, which peeks without resetting). `wifi_reconnects`/`ota` read directly from the router's own `_networking`/`_otaManager` references (constructor-injected, not late-bound — no null guard needed). `stack_high_water` comes from `Telemetry::writeStackHighWaterMarks()`'s static task registry — see [Telemetry's Diagnostics reporting section](../../Telemetry/README.md#diagnostics-reporting) for the full design rationale (F-056 in the feature catalog), including why temperature alone needs local 15s sampling while the other three fields are read once per report.
- **Broadcast vs CommandBus broadcast**: The `broadcastXxx()` helpers on this class send raw pre-serialised strings. `CommandBus::broadcast()` serialises a `CommandResult` and fans it out. They are separate paths; subsystems outside the communication layer use the router's helpers.
- **Handler skipping is silent to clients**: If a reference is null and a handler is not registered, the bus returns `{"status":"ERROR","type":"unknown","message":"Unknown command: ..."}`. There is no boot-time safeguard beyond the `LOG_ERROR` in `registerHandlers()`.