feat(F-038,F-039): bell and clock test fire commands

relay.test_bell  — fire bell N using configured output + duration, non-blocking
relay.test_batch — fire a list of bells simultaneously (single melody step)
clock.test_c1    — fire C1 (ODD) clock output using pulse_duration
clock.test_c2    — fire C2 (EVEN) clock output using pulse_duration

All four bypass bellsEnabled guard intentionally — test commands always fire.
ClockHandler now accepts an optional OutputManager* for the test commands.
CommunicationRouter passes _outputManager to ClockHandler.
Feature catalog updated: F-038 and F-039 added.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
This commit is contained in:
2026-07-10 19:53:54 +03:00
co-authored by Claude Sonnet 4.6
parent e90771a539
commit 07d5b2fb81
6 changed files with 136 additions and 6 deletions
+34
View File
@@ -47,6 +47,8 @@ Every feature — user-facing or significant internal mechanism — is listed he
| F-035 | System aggregate commands (`system.get_config`, `system.get_all`, `system.get_telemetry`) | v2.1.0 | Stable |
| F-036 | Per-subsystem config getters (`log.get_config`, `mqtt.get_config`, `bells.get_config`) | v2.1.0 | Stable |
| F-037 | Network status extended (SSID + MAC in `network.status`) | v2.1.0 | Stable |
| F-038 | Bell test fire commands (`relay.test_bell` / `relay.test_batch`) | v2.1.0 | Stable |
| F-039 | Clock output test fire commands (`clock.test_c1` / `clock.test_c2`) | v2.1.0 | Stable |
---
@@ -492,3 +494,35 @@ Subsystem: `src/Communication/Handlers/LoggingHandler/`, `src/Communication/Hand
- `hostname`: device hostname from `NetworkConfig`
Subsystem: `src/Communication/Handlers/NetworkHandler/NetworkHandler.cpp`
---
### F-038 — Bell test fire commands (`relay.test_bell` / `relay.test_batch`)
Two non-blocking test commands for firing bells on demand, bypassing the `bellsEnabled` guard (manual tests always work regardless of the master switch):
| Command | Behaviour |
|---|---|
| `relay.test_bell` | Fire bell channel N using its configured output and duration. Non-blocking — OutputManager timer handles the shutoff. Can be sent in rapid succession like piano keys. |
| `relay.test_batch` | Fire a list of bell channels simultaneously (like a single melody step). Each bell fires for its own configured duration. |
Both commands read output and duration from `ConfigManager` (same values as real playback). Returns the resolved output and duration so the caller can confirm what was fired.
Subsystem: `src/Communication/Handlers/RelayHandler/RelayHandler.cpp`
---
### F-039 — Clock output test fire commands (`clock.test_c1` / `clock.test_c2`)
Two test commands for verifying clock relay wiring without waiting for the next scheduled clock strike:
| Command | Behaviour |
|---|---|
| `clock.test_c1` | Fire the C1 (ODD) clock output immediately for `pulse_duration` ms |
| `clock.test_c2` | Fire the C2 (EVEN) clock output immediately for `pulse_duration` ms |
Both use `OutputManager::fireClockOutput()` which resolves the physical pin from `ClockConfig`. Returns the output name and actual duration used.
`ClockHandler` constructor now accepts an optional `OutputManager*` (defaults to `nullptr`); the router passes `_outputManager` so the test commands are live when the output manager is registered.